background image

DMUI-EASY2MOVE - OPERATING MANUAL // PAGE 3

CONTENTS

1  General information 

5

1.1  Other applicable documents 

5

1.2 Copyright 

5

1.3  Royalty-free use of images and text 

5

1.4 Trademarks 

5

2 Safety 

6

2.1  Target audience 

6

2.2  General safety regulations 

6

2.3  Intended use  

6

2.4     Reasonably foreseeable misuse 

6

2.5  Explanation of symbols and signal words 

7

2.6 Liability 

7

2.7  Residual risks 

8

2.8  Skilled Persons 

9

2.9  Notes for Resellers 

9

3  Scope of delivery 

9

4 Unpackaging 

10

5 Products 

10

5.1  Key Product Features 

10

5.2 Dimensions 

11

5.3  Drilling Template 

12

6 Assembly 

13

6.1  Safety During Assembly 

13

6.2.1  Required Components 

13

6.2.2 Process 

13

6.2.3  Completing Assembly 

13

7 Operation 

14

7.1  Adjusting the Table Top Height 

14

7.1.1  Moving the Table Top Up 

14

7.2.2  Moving the Table Top Down 

15

7.2  Shelf Stop and Container Stop Positions 

15

Summary of Contents for DMUI-EASY2move

Page 1: ...DYNAMIC MOTION DMUI EASY2move DYNAMIC MOTION system User Manual DOCUMENT VERSION 1 AUGUST 2019...

Page 2: ...ersion 1 0 August 2019 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43...

Page 3: ...ymbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 9 2 9 Notes for Resellers 9 3 Scope of delivery 9 4 Unpackaging 10 5 Products 10 5 1 Key Product Features 10 5 2 Dime...

Page 4: ...r Stop or Shelf Stop Position 16 7 3 Performing a Position Reset Procedure 16 7 4 Factory Reset S0 Reset 16 8 System Information 17 8 Additional Information 18 8 1 Software Dependent Functions 18 8 2...

Page 5: ...es in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentation for height adjustable table systems The license does...

Page 6: ...al worker protection conditions and national safety and accident prevention regulations are observed during operation of the system 2 3 INTENDED USE The DMUI EASY2move is a Paddle Switch Handset for e...

Page 7: ...LOGICDATA products comply with all relevant industry standards which are listed in the product s data sheet However risk can result from incorrect operation or misuse LOGICDATA is in particular not li...

Page 8: ...e housing and cables of the Handset for visible damage Do not install or operate damaged products WARNING Risk of death or serious injury in explosive atmospheres Operating the Handset in potentially...

Page 9: ...ial language INFO The Charter of the French Language La charte de la langue fran aise or Bill 101 Loi 101 guarantees the right of the population of Quebec to conduct business and commercialactivitiesi...

Page 10: ...of the packaging material NOTICE Dispose of the packaging material in an environmentally friendly manner Remember to separate plastic parts from the cardboard packaging 5 PRODUCT The illustrations in...

Page 11: ...UAL PAGE 11 5 2 DIMENSIONS Length 121 82 mm 4 796 Width 47 22 mm 1 859 Height Contact Point to Mounting Point 25 85 mm 1 136 Fig 2 Product dimensions DMUI EASY2move 25 8 5 m m 1 13 6 24 86 mm 0 979 12...

Page 12: ...mmended Mounting Position the DMUI EASY2move is positioned so that the distance from the front edge of the table to the centre of the first Mounting Point is 40 mm The Handset should not protrude from...

Page 13: ...during assembly ensure You have measured the dimensions of the product before assembly All parts areacclimatised to the ambient conditions You do not lift the Handset by its cable INFO Perform a prod...

Page 14: ...all Components have been mounted safely Ensure all Cables are properly connected Ensure that all required Actuators are ready to be operated Do not operate the Table System until it is properly connec...

Page 15: ...VE Key for 10 seconds The Container Stop Shelf Stop Position is saved Container Stop if you are in the bottom half of the movement area Shelf Stop if you are in the top half 7 2 2 DELETE A CONTAINER S...

Page 16: ...parameterized with additional stopping points e g a Container Stop Position repeat Step 3 until the table has moved upwards again 7 4 FACTORY RESET S0 RESET With this function you can reset the DYNAM...

Page 17: ...lease all Keys and wait for 5 seconds Then try to repeat the action again Disconnect the DM System from the Power Unit If a Power Hub is used Disconnect the Power Hub from the Mains Check the Power Un...

Page 18: ...ANING 1 Disconnect the DYNAMIC MOTION system from the mains 2 Wait 30 seconds for residual voltage to dissipate 3 Wipe the Handset with a dry or slightly damp soft cloth Never immerse the Handset in l...

Page 19: ...ftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc Broadmoor Ave SE Suite...

Reviews: