9
♦
Custom Web Page serving… drag and drop Web page designer in
HyperWare-II allows for Web page development employing animated objects
such as motors, pumps, pipes, thermometers, gauges and graphic images.
Build pages showing the process being monitored with embedded real-time
values.
♦
FTP (File Transfer Protocol) data output for periodic automated archiving of
logged data to a remote PC running an FTP Server
♦
Low power design allows for long term field operation from battery
♦
Programmable Analog outputs for sensor excitation and basic control
♦
Four digital inputs user programmable for Event, Count and Frequency
measurement
♦
Four integral alarm outputs including two relays
♦
Integral Compact Flash (CF) card socket for expanded and/or transportable
log memory
♦
HyperNet™ visual icon based programming provides unlimited flexibility in
programming,
yet maintains simplicity with drag and drop icon configuration.
Set the IntelliLogger up without writing any cryptic lines of code or
experiencing the rigors of excruciating two button menu tree nightmares.
♦
Intelligent logging methodologies include logging only upon change of an
input (Delta-Logging), Conditional logging based on input levels, Conditional
logging based on time of day or elapsed time, dual speed logging initiated by
User programmed conditions, and more.
♦
Integral Liquid Crystal Display (LCD) for system status as well as local real-
time display of User defined input and/or calculated values and states
♦
User defined alarm messages
FCC I
NFORMATION
This equipment complies with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
The FCC limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.