14
“Connection Procedures” to
reinstall the regulator properly.
Fire at control
knob
1. Burner is improperly seated on
control valve.
2. Gas connections may be loose.
3. Burner holes may be obstructed.
1. Refer to the section of “To
Reinstall The Main Burners” at
P.31 to reinstall burner properly.
2. Refer to the section of “Leak
Check” to check and tighten all
connections.
3. Refer to the section of “Burner
Cleaning” to clean the burner.
Yellow flame at
burner
1. Burner is obstructed.
1. Refer to the section of “Burner
Cleaning” to clean the burner.
Flame blows
out on “LOW”
1. Burner holes may be obstructed.
2. Grill is not sufficiently preheated.
3. Burner is improperly seated on
control valve.
1. Refer to the section of “Burner
Cleaning” to clean the burner.
2. Preheat the grill for sufficient
time.
3. Refer to the section of “To
Reinstall The Main Burners” to
reinstall burner properly.
Burner does
not get hot
enough
1. Flow control device has been
activated in regulator.
1. Reset the regulator. Turn off all
burners and close the LP tank
valve. Disconnect the regulator
from the LP tank and wait for one
minute. Reconnect the regulator
to the LP tank and slowly open
the LP tank valve until the valve
is fully open. Light all burners and
observe the temperature.
Grill is too hot
1. Excess grease build-up causing
grease fires.
2. Damaged or faulty regulator.
1. Refer to the section of
“Maintenance and Cleaning
instructions” to clean the grill
properly.
2. Replace the damaged parts with
factory authorized component.
GardenStore Nordic AB. Maria Bangata 17, 118 63 Stockholm, Tel: +46 8-622 60 00
Mail: [email protected]