36
5 Maintenance and Cleaning
5.2 Cleaning
This type of dispensing device requires some dismantling when cleaning with high
viscose products. Disassemble only as far as it is necessary for cleaning. During this
activity attention must be paid to the chemical properties and chemical reactions of the
products. Please contact the manufacturer of the used 2K product.
☞
Note!
In certain cases, flushing of the dispensing device may be easier than dismantling and
cleaning the components.
● Set the dispensing device to manual mode and secure against unauthorized operation.
● Remove the static mixer from the mixing head and dispose of in accordance with the
manufacturer instructions.
● Clean the connection thread/bayonet catch and holes.
Pay attention that the two components are not mixed.
● Hold the mixing head with the outlet pointing downwards and clean the holes (outlets)
individually.
Cleaning of the Outlets
Caution!
Disassemble both pressure sensors as a precaution to prevent damage to the sensor
surface. If damaged they cannot be used.
They are accessible when the mixer
1
is
removed.
● Catch withdrawing product and clean
the mixing head again.
Be sure that the
2 components are not mixed.
Use
separate cloths.
● Thread and holes of the mixing head
may protect against dehydration and
pollution, e. g. by a cap at the
appropriate places.
Summary of Contents for MM25