![Loctite 98022 Operation Manual Download Page 8](http://html1.mh-extra.com/html/loctite/98022/98022_operation-manual_1933821008.webp)
7 Troubleshooting
Problem Possible
Cause
Correction
No adhesive is dispensed.
•
Cylinder is in retract mode.
•
Product reservoir is empty.
•
Air pressure is set to low.
•
Flow controls on 3-way
valve is shut down.
•
Blockage downstream of
cartridge pusher.
•
Move hand lever down to
advance ram.
•
Insert new product package
into cartridge sleeve.
•
Check incoming air
pressure (min 60 PSI).
•
Open flow controls on 3-
way valve.
•
Check valve, hose, and
needle.
LED indicator does not light.
•
Connection is loose.
•
Reed switch is not properly
located.
•
Indicator is faulty.
•
Tighten plug connector.
•
See low level set-up
instructions.
•
Replace sensor.
8 Documentation
8.1
Spare Parts
Cartridge
Sleeve
Kit
984826
Kit includes – Cartridge Sleeve
Cartridge
Sleeve
Cap
Plastic
Washer
Reed
Switch
Assembly 984756
Air
Cylinder
984732
Plunger
Ram
984755
8.2 Optional
Accessories
Loctite® ViperLube™ Grease 14 oz. Cartridge
36782
Cartridge
Fitting
Kits:
Poly Fitting 1/4” Tube x 1/4 Male NPT, Qty 10
984832
Poly Fitting
3/8” Tube x 1/4 Male NPT, Qty 10
984833
Fischbach cartridge to 1/4 Female NPT, S.S., Qty. 1
982644
Adapter, Semco Cartridge to 1/4 Female NPT, Qty 3
98181
Adapter, Fitting, Male Luer Lok x 1/4 Male NPT, Qty. 5
98371
Nozzle, 2.5” Long x 1/4 Male NPT, Qty. 10
98128
Feedtube Kits:
Black Teflon® Lined Feedtube, 3/8” x 33 feet
97970
Black Teflon® Lined Feedtube, 1/4” x 33 feet
97972
8