2 Description
(Continued)
A reed switch assembly is located on the air cylinder. The use of this switch is optional.
This switch is equipped with an LED indictor and a connector has been installed to
interface with Loctite® Single Function Controller 98023 or Three Function Controller
98024. The reed switch is activated by a permanent magnet located on the piston within
the air cylinder. As product is dispensed out of the 300 ml package, the piston will
move forward and activate the reed switch. Once activated the LED indicator will light
up and the switch will communicate a low level condition to the controller.
The 300 ml Cartridge Pusher is outfitted with a grease fitting located on the main
housing. This fitting allows access to a grease reservoir, which surrounds the piston
shaft applying a generous coating of grease during use. This grease protects the surface
of the shaft and the cylinder seals from adhesives or other contaminants.
3 Technical
Data
Pneumatic
Supply
Min
50
PSI
Max
100
PSI
Air
Quality
Filtered
10
um,
oil-free,
non-condensing
Pneumatic
Hose
Size
Minimum
4mm
I.D.
Dimensions
W x H x D, 5 ½” x 8
3/8
” x 26 ¾”
Operating Temperature
10
°
C to 40
°
C (50
°
F to 104
°
F)
Weight
10.6
Lbs.
(
4.8
kg)