18
5 Dispensing
5.3.2
Cont
inuous Mode
This mode of operation is used for the application of beads.
•
With the pressure regulator
12
set the dispensing pressure to 0.5 bar (approx. 7 PSI).
•
Press the buttons and simultaneously.
The lighting of the LED “CONT.“ indicates
Continuous mode. The display of the
dispensing time in the digital display is set
to
con
.
•
Press the button (or the foot switch) to
check if the product is ejected quickly enough
from the dispensing needle.
When the dispensed quantity is achieved too slowly:
•
Increase the dispensing pressure or repeat this sequence with a larger dispensing needle.
– Switching back to time controlled mode without storage of the dispensing time by renewed
pressing of button or . The LED extinguishes. In the digital display, the dispensing time
is blinking.
– Switching back to time controlled mode with storage of the dispensing time by
pressing button . The LED extinguishes. The indicated dispensing time is stored.
CONT
CONT
CONT