12
2 Description
15
Button
Button for the storage of the new values set for the
dispensing time [s].
When the indication of the dispensing time [s] in the
digital display blinks, the indicated dispensing time
is stored by pressing button and the display stops
blinking.
16
Button
Button for filling the product feedline. In both modes
the product is dispensed as long as button is
pressed.
– In time-controlled mode, the dispensing time is
not changed.
17
Buttons
Buttons for changing the dispensing time for a
dispensing sequence.
When button or is pressed, the display
of the dispensing time [s] in the digital display begins to blink. The dispensing time is adjustable
from 0.01 to 99.9 s.
Buttons for switching from time controlled mode to
cont
inuous mode.
With the simultaneous pressing of the buttons for more than 0.5 seconds, an operating mode
change takes place to the
Cont
inuous
mode. In the display, “
con
” appears. The lighting of the
LED “CONT.“ indicates
Cont
inuous
mode.
During dispensing, the elapsed dispensing time is indicated in the digital display beginning each
time with 0.00 s. The last dispensing time remains displayed until the next start.
– Switching back to time controlled mode
without storage
of the dispensing time by renewed
pressing of button or . The LED extinguishes. In the digital display, the dispensing time
is blinking.
–
Switching back to time controlled mode
with storage
of the dispensing time by pressing
button . The LED extinguishes. The indicated dispensing time is stored.
18
Digital Display
Three-figure Display of the dispense time [s].
19
LED “CONT“
The lighting of the red LED “CONT“ indicates Continuous mode.
CONT
CONT
15
16
17
18
19
Summary of Contents for 97007