13
5.10 Set: Low Level Mode
1. Press
, the setting for Low Level mode start to flash.
2. Press
for switching between “OFF”, “LAMP” and “LAMP + STOP”.
3.
After completed setting, press
to save and exit.
Notice:
OFF: Only digital output from XS1
LAMP: Digital output from XS1 + LED Light on control panel
LAMP + STOP: Digital output from XS1 + LED Light on control panel + System Stop
Notice:
The level sensor MUST be adjusted according to the type of product used, the size of the bottle,
and orientation of the basket with spacers, in order to function properly.
5.11 Set: Lock-Out Mode
1. Press
, the setting for Lock-Out mode start to flash.
2. Press
for switch between “ON” and “OFF”.
3.
After completed setting, press
to save and exit.
Notice:
Lock-Out Mode “ON” means all setting in the system can’t be change by pressing
button.
Otherwise “Setting Locked Call Supervisor” will show on the display.
Press both
+ to change the setting when Lock-Out Mode is “ON”.
5.12 Adjust the Level Sensor
Before adjusting the Level Sensor
1.
Empty a bottle of the product you use.
2.
Leave as much residue in the bottle as is required in order to prevent air getting into the
product feed line.
3.
Insert the product bottle. For small bottles use the bottle nesting block.
4.
Check that the product bottle inserted into the bottle nesting block is pressed against the
level sensor. Only then the correct adjustment of the level sensor is possible.
Procedure to Adjust the Level Sensor:
1.
Turn the system power “ON”.
2.
Remove the metal screw from the level sensor.
3.
With an electrician’s screwdriver, find the point at which the
sensor switches to the condition inactive. The LED is OFF”.
4.
Check this adjustment with a full bottle and an empty bottle.
Notice:
The correct adjustment is exactly the point when the sensor switches “OFF”.
Do not go beyond that point!
Summary of Contents for 1390321
Page 6: ...6 2 4 Overall Dimensions ...
Page 17: ...17 ...