III. 

PROGRAMMING 

Programming  is  the  process  of  setting  the  access  code  and  access  time.  The  access  time  is 

normally set to 6 seconds. The access code may be any number from three to eight digits in 
length.  If you experience problems programming, contact LockNet. 

 

A. 

A

CCESS

 C

ODE

 

1. 

The code is factory set at 

4-4-4-4

2. 

To change the code, press the PROGRAM button on the control module. 

2. 

Press “1” then “#” on the keypad.

 

3. 

Enter the new code (4 digits typically) on the keypad. 

4. 

Press 

“#”on the keypad (ends entry).

 

5. 

Press  

* *

  on the keypad (returns to normal operation). 

6. 

Test the new access  code by entering it on the  keypad and pressing #. The solenoid 
should  energize  to  unlock  the  door  for  approximately  six  seconds.    After  the  access 
period the door should automatically relock when shut.  If necessary, program the access 
time (refer to next section B). 

 

B. 

A

CCESS

 T

IME

 

1. 

On the control module, press the PROGRAM button. 

2. 

Press “2” then “#” on the keypad.

 

3. 

Enter the access time (two digits, in seconds) “0

-

6” on the keypad.

 

4. 

Press “#” on 

the keypad (ends entry). 

5. 

Press 

* *

 on the keypad (returns to normal operation). 

6. 

Test the release time by entering the access code and pressing #.  The solenoid should 
energize to unlock the door for approximately six seconds. After the access period the 
door should automatically relock when shut. 

 

IV. 

COMPLETING WORK 

After the labor is complete and the system is tested, complete final paperwork and sign-offs 

before leaving the job site. 

1. 

Test the system to ensure proper operation of all installed components. 

2. 

Call LockNet to report job completion (after normal business hours you may call LockNet the 
following business day). 

3. 

When you are satisfied, demonstrate the system operation to the store manager. 

4. 

Turn over all keys to the store manager. 

5. 

The store manager must sign the installer payment form. 

6. 

Fax a copy of the sign-off sheet, attn. LockNet Customer Service, to 1-859-887-4958. 

7. 

Contact LockNet immediately if you have problems completed any step in this section. 
 

 