LockNet DKYSLRH Installation Instructions Download Page 2

LockNet Security Doors

 

Document Part # 14003524 (Rev 021919) 

 

Page 2 of 5  

READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING WORK! 

 

I. 

PREPARATION 

Before installing, check your parts inventory, make certain the door itself is operating correctly, 

and remove existing exit device. 

A. I

NVENTORY

 

1. 

Open, unpack, and inventory your DKYSLRH (right-hand) or DKYSLLH (left-hand) kit. 

2. 

If any items are missing, contact LockNet immediately. 

3. 

You will need the following tools:  

Drill with 1/8” bit, 1/4” bit, 1 1/8” hole saw; 7/16” 

deep 

socket

; 3/8” open end wrench, 7/16” open end wrench, 

torx T25 security wrench (supplied 

with panic bar), as well as common hand tools including screw drivers, tape measure, 
level, and hammer. 

B. D

OOR

 

1. 

Check the existing door for proper operation. 

2. 

If the door does not operate properly, stop installation and contact LockNet immediately. 

C. R

EMOVE

 O

LD

 E

XIT

 D

EVICE

 

1. 

Remove any existing exit hardware from the door. 

2. 

Use the cover plates provided with your kit to cover any lock cutouts (if necessary). 

II. 

INSTALLATION 

Major components should be installed in the order shown. Before proceeding, make certain you 

know where you are physically going to mount the keypad (on the face of the door), and where 
the  transformer  will  be  plugged  in.  Refer  to  Figures  3  and  4  when  determining  component 
mounting locations. 

A. S

UR

-L

OCK

 I/O 2000EE P

ANIC

 B

AR

 

1. 

Using the template supplied, mark and drill installation holes for the Sur-Lock panic bar. 

2. 

Mount the Sur-Lock to the door (refer to the Sur-Lock 2000EE Installation Instructions). 

3. 

Mount  the  exterior  keypad  to  the  door  (refer  to  the  Sur-Lock  2000EE  Installation 
Instructions).  Alternately, you may mount the keypad in a different location on the door 
using the longer keypad cable supplied in the kit (see Figure 4). 

4. 

Mount the armored loop cable to the door and frame (see Figure 3). 

5. 

Attach the strain relief on the armored cable coming from the side of the Sur-Lock unit 
through the cover plate for the armored door loop cable. 

6. 

Connect the Sur-Lock cable and the armored door loop cables using the attached plugin 
connectors. 

7. 

Mount the cover onto the armored door loop cable. 

Reviews: