8. 

Attach the strain relief on the armored power supply cable through the cover plate for 
the armored door loop cable. 

9. 

Connect the armored power supply cable and the armored door loop cables using the 
attached plug-in connectors. 

10. 

Mount the cover onto the armored door loop cable. 

11. 

Connect  the  transformer  and  the  armored  power  cable  using  the  attached  plug-in 
connectors. 

12. 

Make sure the 

ON/OFF

 switch on the Sur-Lock unit is in the 

OFF

 position. 

13. 

Plug the transformer into a wall receptacle.  Make sure that the wall receptacle chosen is 

NOT

 controlled by a switch and that it is on at all times. 

14. 

Turn the 

ON/OFF

 switch on the Sur-Lock unit to the 

ON

 position. 

15. 

Test the panic bar to make sure it latches and unlocks properly.  If necessary, adjust the 
panic bar to insure proper operation. 

 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Interior Side 

Exterior Side 

Figure 3: 
Normal Keyless System 
Component Mounting 
Locations

 

 

Keypad

 

Transformer

 

Armored Cable

 

Armored

 

Door Loop

 

Sur-Lock Exit

 

Device

 

Transformer

 

Armored Cable

 

Armored

 

Door Loop

 

Sur-Lock Exit

 

Device

 

Keypad

 

Figure 4: 
Alternate Mounting 

Locations For Keyless 
System

 

 