1. Important safety information 

Carefully read and follow all safety precaution and warnings before attempting to install and use 

this operator, incorrect installation can lead to severe injury. 

 

The gate operator should be installed by a qualified technician; otherwise, serious personal 

injury or property damage may occur. 

 

The auto-reverse function must be checked during installation to ensure that the gate can 

auto-reverse in the event of obstruction. 

 

This auto-reverse function should be regularly inspected and adjusted, if necessary. 

 

When opening or closing the gate, do not attempt to walk or drive through the gate. 

 

Children should not be allowed to play near or operate automatic gates. 

 

The automatic gate operator must be grounded.

 

 

Install the gate operator on the inside of the property, DO NOT install it on the outside of 

the property where the public has access to it. 

 

Be careful when in close proximity to moving parts where hands or fingers could be 

pinched. 

 

Do not allow control devices to be placed so that a person can access them by reaching 

through the gate. 

 

In the event of power failure, an emergency release key allows you to operate the gate 

manually. 

 

The operator should be switched off before repairing it or opening its cover. 

 

Please erase and reprogram the code after installing the operator. 

 

2. Main features 

 

The device is used to drive sliding gate. 

 

For your safety, the DKC400 (U) Y will stop and reverse if it was obstructed on closing and 

stop when it was obstructed on opening. 

 

Supports up to 100 remote controls. 

 

User programmable and user erasable remote codes. 

 

Infrared terminal (N.C) is supplied to use. 

 

Auto-close feature is available for this operator. 

 

Pedestrian mode. 

 

Manual key release design for emergency purposes. 

 

3. Main technical parameters

 

Type DKC400Y 

DKC400UY 

Power supply:

 

AC 220V, 50Hz 

AC110V, 60Hz 

Motor speed

 

1400 r/min

 

1680 r/min 

Gate moving speed

 

14m/min (24 teeth) 

11m/min (19 teeth)

 

17 m/min (24 teeth)   

13m/min (19 teeth)

 

Output torque

 

14N

·

m

 

 

Summary of Contents for Aleko AR1400

Page 1: ...Sliding Gate Operator User s Manual Lockmaster DKC400UY Lockmaster DKC400U Aleko AR1400 www Openers4less com Sales Openers4less com 352 241 8259...

Page 2: ...AL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Main technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 4 6 Connecting 7 7 Control 10 8 Che...

Page 3: ...DKC400UY...

Page 4: ...c8 4 9 Base plate for receiver limit switch sensor LockMaster tr3bp9 1 10 Base plate for control board LockMaster tr3bp10 1 11 Plastic clip LockMaster tr3pc11 4 12 Receiver LockMaster tr3rec12 1 13 La...

Page 5: ...the use of various tools shown below Other tools may be required as needed for the installation of the concrete pad and electrical connection Table 3 Required Tools for Installation Screwdriver Tape M...

Page 6: ...as access to it Be careful when in close proximity to moving parts where hands or fingers could be pinched Do not allow control devices to be placed so that a person can access them by reaching throug...

Page 7: ...switch on the motor automatically when the temperature is lower than 85 C 5 C 5 Installation and adjustment The DKC400 U Y rack driven gate operator operates by forcing a drive rack past a drive gear...

Page 8: ...is possible mount the gate operator on installation pad as shown in Fig 2 Check the operator and make sure it is lined up with the gate Nut Bolt Anchor Nut Spring washer Plain washer Gear Gate operat...

Page 9: ...e sliding gate manually to pre determine the position Solder the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close posi...

Page 10: ...ing Plate as shown below Step 3 Install the Receiver onto the Motor by mounting it on the small white clips that are on the small Mounting Plate as shown below Step 1 Unscrew the Blue Cover from the M...

Page 11: ...1 RED WIRE Terminal 12 YELLOW WIRE any Terminal 13 YELLOW BLUE WIRE any Terminal 14 BLUE WIRE any Step 5 Next take the set of wires coming from the motor and connect the red and black wires anywhere o...

Page 12: ...Blue wires on it Connect the plug on to the Control Board on the section labeled LIMIT SWITCH as shown on the pic right Step 8 Find the wire coming from the bottom of the Motor that is GREEN YELLOW S...

Page 13: ...ature 12 5 Seconds 25 Seconds 45 Seconds only one dip switch should be ON The other two dip switch should be in the OFF position for the auto close feature to work correctly DI P 2 DI P 3 DI P 4 Direc...

Page 14: ...de compatible blue button on remote control transmitter The red and black wires are 24 volt power input The two yellow are the channel 1 the two white are channel 2 and the black wire is the antenna w...

Page 15: ...Residential Sliding Gate Operator Optional Equipment Installation Procedures O O O O O O O O O O O O Blue Brown Black White Grey Grey Black Black Green Brown Red Black...

Page 16: ...lose time of pedestrian See Set auto close function of pedestrian mode section The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 1 DIP switch Connectin...

Page 17: ...2005 2009 LockMaster All Rights Reserved sales Openers4Less com www Openers4Less com...

Reviews: