2

 

4.

 

After the lock is mounted to the door, place the proper spindle into center / spindle hole.   You may need to 
use the right twist or left twist depending on the knob / lever turn direction. 

a.

 

Note:  Your tail piece may need some type of stop in the panic exit bar (+) receiver to keep the tail 
piece from moving.  

If the panic exit “+” cam is “open” so the Spindle can slide through (ie: 

Monarch), place a burr on the “+” side of the Spindle approximately 3/8” from the end.  This 
will  assure  the  Spindle  will  not  interfere  with  the  latch  operation  or  slide  out  of  the 
combination body.   

b.

 

IMPORTANT:

    The  spindle  used  must  allow  the  combination  lock  to  fully  turn  to  clear  the 

combination.  If the combination does not clear after opening the panic bar, you will need to use 
the less twisted spindle.  This will allow the lock to open the panic bar and clear the combination 
lock. 

 

These combination locks are designed with a (“C”) button to clear the combination  

The 115-P and 285-P have a passage function.  To operate the passage function, refer to How To Change Code.   

**After installation, to change the code, you must remove the panic bar, and then remove the lock. ** 