MODELS: 310P – 285P – 115P
2
4.
After the lock is mounted to the door, place the proper spindle into center / spindle hole. You may need to
use the right twist or left twist depending on the knob / lever turn direction.
a.
Note: Your tail piece may need some type of stop in the panic exit bar (+) receiver to keep the tail
piece from moving.
If the panic exit “+” cam is “open” so the Spindle can slide through (ie:
Monarch), place a burr on the “+” side of the Spindle approximately 3/8” from the end. This
will assure the Spindle will not interfere with the latch operation or slide out of the
combination body.
b.
IMPORTANT:
The spindle used must allow the combination lock to fully turn to clear the
combination. If the combination does not clear after opening the panic bar, you will need to use
the less twisted spindle. This will allow the lock to open the panic bar and clear the combination
lock.
These combination locks are designed with a (“C”) button to clear the combination
The 115-P and 285-P have a passage function. To operate the passage function, refer to How To Change Code.
**After installation, to change the code, you must remove the panic bar, and then remove the lock. **