1

 

PARTS LIST 

310-P  285-P  115-P 

1.  Outside Body 

1  

1  

1  

2.  Rubber Escutcheon 

3.  Hex Bolts 

4.  Flat Spindle 

5.  Spindle with twist (35

°

) (R & L) 

6.  Spindle with twist (45

°

)( R & L) 

7.  Screw x 30 mm. 

2  

4  

8.  Screw x 40 mm. 

2  

2  

4  

9.  Wafer, blue 

2  

2  

2  

10.  Wafer, red (active) 

2  

2  

2  

11.  Washer, flat 

2  

2  

4  

12.  Finish Washer 

2  

2  

4  

13.  Tweezer 

1  

1  

 
These combination locks are  designed to  replace your keyed cylinder on panic exits.  They will work  with most 
panic  exits  with  a  90°  turn  radius  or  less.    They  may  need  some  modifications  to  work  with  some  panic  bars.  
Because so many panic exit devices are manufactured under different brand names we cannot identify all panic bars 
that our locks are compatible with. 

Set Combination: 

Set the code to desired combination before placing to door.  Use How to Change Code instructions to change code.  
Be sure to hold the “C” (clear bottom) while changing code. 

 Installation: 

The 310P panic exit device is set up and ready for clockwise or counter clockwise operation. It may, however; need 
to be calibrated for use with the specific panic exit device. 

The  115P  and  285P  panic  exit  device  is  set  up  for  replacement  or  new  installation  with  Lever  operation.  It  may, 
however need to be calibrated for use with the specific panic exit device. 

Position on Door: 

1.

 

After panic exit is installed on door, determine the center of the tail piece hole on the outside of door. Place 
the template over the center hole from the standard rim cylinder 1 ¼”.  Mark top and bottom mounting holes 
to mount the combination body to the door.   The center hole will be where the tail piece is to be placed, from 
combination body to panic bar. 

2.

 

Drill mounting holes: 

a.

 

New Installation:  Drill either  3/8” mounting holes at the top and bottom for the lock mounting, 
and a 1 ¼” hole in the lower center tail piece hole, (whichever is most convenient) 

b.

 

Retro Fitting:  If the current hole is 2” or less, proceed with paragraph 3.  If existing hole is larger 
than 2 ½” you may need a larger escutcheon to cover the existing hole, or purchase the push / pull 
plate from LockeyUSA to cover a large hole in the door. 

3.

 

Place the rubber escutcheon on the back of the lock body and mount the combination lock to the door using 
the supplied finish washers and screws. 