ATTENTIONS
1
+
Electric lock
Diode
500mA
Power supply
Electric Locks
+ External
Relay
AC 24V
1.Power Supply requirement: DC 12V 500mA or above.
2.Door opening or alarm connector output: Maximum load of 1A@12VDC.
Connect with external RELAY to control higher voltage or current .
3.Electric Lock: Fail-safe or Fail-secure type (Refer to p13).
Please note: In order to protect the proximity unit, please connect one Diode
between two power supply connectors of electric lock to absorb surge.
4.Please use 24AWG and above of double shieled twisted pair wire for communication
wires.
5.Avoid installing the unit at the following environment:
A. Machines with the same frequency as the proximity unit around the neighborhood.
B. In the area of a base station with radio or wireless transmission.
C. On metal wall (proximity distance will be shorten).
6.It is suggested to separate the power supply of electric lock and proximity unit in order
to stabilize the power supply.
7.It is IP54 waterproof and its surface is completely waterproof. Please apply waterproof
silicone on its base if it is mounted on rough surface to make sure its base is waterproof.
8.Do not place communication and power supply wires at the same route in order to
prevent interference which might cause abnormal communication.
9.Communication methods: Use of RS-485, TCP/IP, USB interfaces to connect
with computer.
Too close
Too close
Sharing the same
power supply
Proximity distance
becomes short
Metal
1234567890
1234567890
18838:00722
Card number in the back of the card
Example of the card
The last 8-digit number of 1234567890 is 34567890.
125KHz(EM)
Card number
Chip serial number
(non-serial)
Card number
(serial)
13.56MHz(MIFARE)
X
X
X
DC 12V
X
X
~
~
AC
24AWG
Wires
Communication wire
DC 12V
Lock Control -
Kouterbaan 63