background image

              

User’s Information Manual

6

1  

Maintenance schedule

Maintenance procedures

Pool heater must be serviced and maintained

WARNING

The pool heater must be inspected and started 
annually at the beginning of the heating 
season by a qualified service technician.  In 
addition, the maintenance and care of the 
pool heater designated on page 5 of this 
manual and explained on pages 6 and 7 
must be performed to assure maximum pool 
heater efficiency and reliability. Failure to 
service and maintain the pool heater and 
system could result in equipment failure, 
causing possible severe personal injury, 
death, or substantial property damage.

 NOTICE

The following information provides detailed 
instructions for completing the maintenance 
items listed in the maintenance schedule on 
page 5.  In addition to this maintenance, the 
pool heater must be serviced and started up 
at the beginning of each heating season by a 
qualified service technician.

Check pool heater area

WARNING

To prevent potential of severe personal 
injury, death, or substantial property 
damage, eliminate all materials discussed 
below from the pool heater vicinity and the 
vicinity of the pool heater combustion air 
inlet.  If contaminants are found:
Remove products immediately from the 
area.  If they have been there for an extended 
period, call a qualified service technician to 
inspect the pool heater for possible damage 
from acid corrosion.
If products cannot be removed, immediately 
call a qualified service technician to 
re-pipe vent and air piping and locate 
vent termination/air intake away from 
contaminated areas.

1.  Combustible/flammable materials -- Do not store 
 

combustible materials, gasoline or any other flammable 

 

vapors or liquids near the pool heater. Remove 

 

immediately if found.

2.  Air contaminants -- Products containing chlorine or 
 

fluorine, if allowed to contaminate the pool heater intake 

 

air, will cause acidic condensate in the pool heater.  This will 

 

cause significant damage to the pool heater if allowed to 

 

continue.   

Check vent piping

1.  Visually inspect the flue gas vent piping for any signs of 
 

blockage, leakage, or deterioration of the piping.  Notify 

 

your qualified service technician at once if you find any 

 problems.

WARNING

Failure to inspect the vent system as noted 
above and have it repaired by a qualified 
service technician can result in vent system 
failure, causing severe personal injury or 
death.

Check air inlet piping (if applicable)

1.  Visually inspect the air inlet elbow to be sure it is 
 

unobstructed.  Inspect the entire length of air piping to 

 

ensure piping is intact and all joints are properly sealed.

2.  Call your qualified service technician if you notice any 
 problems.

Check relief valve (if applicable)

1.  Inspect the pool heater relief valve and the relief valve 
 

discharge pipe for signs of weeping or leakage.

2.  If the relief valve often weeps, immediately contact your 
 

qualified service technician to inspect the pool heater 

 and 

system.

 

CAUTION

Be sure to shut the pool heater OFF when 
backwashing the filter.

Summary of Contents for EnergyRite ER152

Page 1: ...e likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a ne...

Page 2: ...RNING CAUTION CAUTION NOTICE DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if...

Page 3: ...by the manufacturer s warranty see Water Connections in the EnergyRite Installation and Operation Manual Checking equipment Upon receiving equipment check for signs of shipping damage Pay particular a...

Page 4: ...eater never violate the following safety rules 1 Pool heaters are heat producing appliances To avoid damage or injury do not store materials against the pool heater or the vent air intake system Use p...

Page 5: ...ition and flame sense electrodes sand off any deposits clean and reposition Check wiring and connections Perform start up checkout and performance verification per Section 9 in the EnergyRite Installa...

Page 6: ...oducts cannot be removed immediately call a qualified service technician to re pipe vent and air piping and locate vent termination air intake away from contaminated areas 1 Combustible flammable mate...

Page 7: ...tinues to weep afterwards contact your qualified service technician to inspect the valve and system 4 If water does not flow from the valve when you lift the lever completely the valve or discharge li...

Page 8: ...User s Information Manual 8 2 Operating instructions...

Page 9: ...ings POOL SPA OFF DOWN UP RESET MENU DISPLAY SCREEN Figure 3 1_ Control Panel NOTE The control must be unlocked before adjustments can be made When locked the display will alternate between its curren...

Page 10: ...he Service Menu Please reference the EnergyRite Service Manual for a detailed description of the Service Menu Status Display Screens Display shows Description Control OFF The control module has been p...

Page 11: ...11 NOTES...

Page 12: ...10 Revision C ECO C13449 reflects the addition of the backwash caution on page 6 Revision D PCP 3000004413 CN 500004678 reflects an update to SAP material numbers Revision E PCP 3000033199 CN 5000219...