User’s Information Manual

10

3  

EnergyRite control module

Access modes

Modes of operation

There are three modes of operation:  1) Off, 2) Pool, and     
3) Spa.  The factory default mode is Off.

Off mode

When in Off Mode the control will display CONTROL OFF 
and will not monitor any of the inputs.

Setup menu

Additional features can be accessed and adjusted through the 
Setup Menu.  Please reference the EnergyRite Service Manual 
for a detailed description of the Setup Menu.

Service menu

Temperature rise and data logging information can be accessed 
from the Service Menu.  Please reference the EnergyRite Service 
Manual for a detailed description of the Service Menu.

Status Display Screens

Display shows:

Description

Control: OFF

The control module has been placed in the Off Mode.

Pool:  Standby

The unit has not received a call for heat.

Pool Temp = ***°F

Indicates the current inlet water temperature.

Pool Mode Prepurge

A call for heat has been initiated. The blower has been powered and 
the air pressure switch has closed. 

Pool Mode Ignition

After the prepurge period, the unit has begun a spark period to light 
the main burners.

Pool:  Heating

The burners have fired and the flame has been detected.

Standby

Remote is active and has either satisfied the set point or there is no 
call for heat from the remote.

Summary of Contents for EnergyRite ER152

Page 1: ...e likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a ne...

Page 2: ...RNING CAUTION CAUTION NOTICE DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if...

Page 3: ...by the manufacturer s warranty see Water Connections in the EnergyRite Installation and Operation Manual Checking equipment Upon receiving equipment check for signs of shipping damage Pay particular a...

Page 4: ...eater never violate the following safety rules 1 Pool heaters are heat producing appliances To avoid damage or injury do not store materials against the pool heater or the vent air intake system Use p...

Page 5: ...ition and flame sense electrodes sand off any deposits clean and reposition Check wiring and connections Perform start up checkout and performance verification per Section 9 in the EnergyRite Installa...

Page 6: ...oducts cannot be removed immediately call a qualified service technician to re pipe vent and air piping and locate vent termination air intake away from contaminated areas 1 Combustible flammable mate...

Page 7: ...tinues to weep afterwards contact your qualified service technician to inspect the valve and system 4 If water does not flow from the valve when you lift the lever completely the valve or discharge li...

Page 8: ...User s Information Manual 8 2 Operating instructions...

Page 9: ...ings POOL SPA OFF DOWN UP RESET MENU DISPLAY SCREEN Figure 3 1_ Control Panel NOTE The control must be unlocked before adjustments can be made When locked the display will alternate between its curren...

Page 10: ...he Service Menu Please reference the EnergyRite Service Manual for a detailed description of the Service Menu Status Display Screens Display shows Description Control OFF The control module has been p...

Page 11: ...11 NOTES...

Page 12: ...10 Revision C ECO C13449 reflects the addition of the backwash caution on page 6 Revision D PCP 3000004413 CN 500004678 reflects an update to SAP material numbers Revision E PCP 3000033199 CN 5000219...

Reviews: