Dual Fuel Supplemental Manual

Ratings

Crest

AHRI Rating

Model Number

Note: Change “N” to 

 “L” for L.P. gas models.

Input
MBH

(Notes 4 - 8)

  

 

             

       Min              Max

Gross

Output

MBH

(Note 1)

Net

AHRI

Ratings

Water,

MBH

(Note 2)

FB(N,L,D)2500

125

2500

2300

2000

FB(N,L,D)3000

150

3000

2760

2400

FB(N,L,D)3500

200*

3500

3220

2800

FB(N,L,D)4000

335

4000

3720

4043

FB(N,L,D)5000

500

5000

4650

3235

Maximum allowed working pressure is located on the rating plate.

 NOTICE

Notes:

1.   The ratings are based on standard test procedures 

prescribed by the United States Department of Energy.

2.  Net AHRI ratings are based on net installed radiation of 

sufficient quantity for the requirements of the building 
and nothing need be added for normal piping and pickup.
Ratings are based on a piping and pickup allowance of 
1.15.  

3.  Crest boilers require special gas venting.  Use only 

the vent materials and methods specified in the Crest 
Installation and Operation Manual.  

4.  Standard Crest boilers are equipped to operate from sea 

level to 4,500 feet 

only

 with no adjustments.  

5.  High altitude Crest Models 2.5, 3.0 and 3.5 boilers are 

equipped to operate from 3,000 to 12,000 feet and high 
altitude Crest Models 4.0 and 5.0 boilers are equipped to 
operate from 3,000 to 5,500 feet.  High altitude models 
are manufactured with diff erent control parameters for 
high altitude operation, but the sequence of operation 
given in this manual remains the same as the standard 
boilers.  A high altitude label (as shown in FIG A.) is also 
affi

  xed to the unit.

6.  Standard Crest boilers will de-rate by 2.2% for each 1,000 

feet above sea level up to 4,500 feet when combustion 
calibration is performed and CO

2

’s are adjusted to the 

recommended levels.

UNIT EQUIPPED FOR

HIGH ALTITUDE

3,000 FT. TO 12,000 FT.

Figure A High Altitude Label Location

*For LP models the minimum input is 420 MBH.

7.  High altitude Crest Models 2.5, 3.0 and 3.5 will de-rate by 

1.4% for each 1,000 feet above sea level up to 5,500 feet and 
1.8% for each 1,000 feet above 5,500 feet.

8.  High altitude Crest Models 4.0 and 5.0 will not de-rate up to 

5,500 feet.

9.  For Crest Models 4.0 and 5.0, installations above 5,500 feet 

contact the factory.

10.  Ratings have been confi rmed by the Hydronics Section of 

AHRI.

5

Other Specifications

Appliance 

Water 

Content 

Gallons

Pipe 
Size

Outlet

Pipe 
Size

Inlet

Gas Inlet 

Size

Air 

Size

Vent 

Size

(Note 3)

Weight 

w/Water

(lbs.)

161

4"

4"

2"

8"

9"

3650

181

4"

4"

2"

10"

10"

4125

215

4"

4"

2"

10"

10"

4750

291

4"

4"

2 1/2"

12"

12"

6500

380

4"

4"

2 1/2"

14"

14"

8000

Summary of Contents for CREST 2.5

Page 1: ...Crest Installation and Operation Manual and the Crest Service Manual before installing Perform steps in the order given Failure to comply could result in severe personal injury death or substantial property damage WARNING Save this manual for future reference FBD SUP_100161023_2000004585 Rev D Dual Fuel Supplemental Manual Models FBD 2 5 5 0 ...

Page 2: ...us situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage HAZARD DEFINITIONS 2 PLEASE READ BE...

Page 3: ...ternal to the appliance Do not use this boiler if any part has been under water The possible damage to a flooded appliance can be extensive and present numerous safety hazards Any appliance that has been under water must be replaced When calling or writing about the boiler Please have the boiler model and serial number from the boiler rating plate Consider piping and installation when determining ...

Page 4: ...s flowing 8 Large natural gas valve Valve 2 Natural The large natural gas valve senses the negative pressure created by the blowers allowing gas to flow only if the gas valves are powered and combustion air is flowing 9 Large propane gas valve Valve 2 Propane The large propane gas valve senses the negative pressure created bytheblowers allowinggastoflowonlyifthegasvalvesarepowered and combustion a...

Page 5: ...and high altitude Crest Models 4 0 and 5 0 boilers are equipped to operate from 3 000 to 5 500 feet High altitude models are manufactured with different control parameters for high altitude operation but the sequence of operation given in this manual remains the same as the standard boilers A high altitude label as shown in FIG A is also affixed to the unit 6 Standard Crest boilers will de rate by...

Page 6: ...g to the appliance 13 Remove the manometer from the pressure tap on top of the gas valve Remove the 1 8 3 mm field supplied fitting and reinstall the pipe plug removed in Step 3 DO NOT adjust or attempt to measure gas valve outlet pressure Attempting to alter or measure the gas valve outlet pressure could result in damage to the valve causing potential severe personal injury death or substantial p...

Page 7: ...es Gas valve replacement The gas valve MUST NOT be replaced with a conventional gas valve under any circumstances As an additional safety feature the gas valves have flanged connections to the venturis and blowers Figure 1 1 Inlet Gas Supply Check_Natural DO NOT adjust or attempt to measure gas valve outlet pressure Attempting to alter or measure the gas valve outlet pressure could result in damag...

Page 8: ...coming gas pressure less than 4 inches w c 99 kPa If none of the above corrects the problem refer to the Troubleshooting Section of the Crest Service Manual Check system and boiler Check water piping 1 Check system piping for leaks If found shut down the boiler and repair immediately See WARNINGS in the Crest Installation and Operation Manual startup regarding failure to repair leaks 2 Vent any re...

Page 9: ...o inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burn...

Page 10: ...ice Maintenance Screen place heater into Service Mode by selecting the START button then selecting Set Gas Valve 1 High 6 Insert the probe from a combustion analyzer into the hole left by the removal of the flue temperature sensor 7 Once the heat exchanger has modulated up to rate measure the combustion The values should be in the range listed in Table 2A CO levels should be less than 200 ppm for ...

Page 11: ...on the ball valves for the ones in use 3 total 5 Turn the main power ON 6 Using the Touch Screen accept the appropriate personality identification as shown in FIG 2 4 Figure 2 4 Personality Plug Screen Figure 2 2B Fuel Selector Switch Models 4 0 5 0 IMG00063 NATURAL PROPANE DETAIL MAIN POWER SWITCH NATURAL PERSONALITY I D PROPANE PERSONALITY I D FUEL SELECTION SWITCH IMG00555 ...

Page 12: ...J3 6 LWCO BOARD J3 3 J3 2 J2 1 J2 2 X6 3 R O K B R O K B R O TEST SWITCH LWCO PROBE R O R O LWCO RESET X6 5 X6 15 BLOWER PROVING SWITCH LARGE R O X6 12 BLOWER PROVING SWITCH SMALL T X13 1 BLOCKED FLUE SWITCH R P X6 6 BLOCKED DRAIN SWITCH K B ENABLE X8 3 X8 8 X8 2 X8 4 X8 9 X7 1 X7 5 X7 2 X7 6 INLET SENSOR OUTLET SENSOR S9 OUTLET SENSOR S1 FLUE SENSOR FLUE SENSOR S10 PRE MIX SENSOR 1 S11 PRE MIX SE...

Page 13: ...0V TANK SENSOR OUTDOOR SENSOR 0 10V 0 10V BMS IN SYSTEM PUMP IN SHIELD SHIELD A B CASCADE LARGE CONNECTION BOARD CN6 1 CN3 6 CN3 7 CN3 14 CN3 13 CN3 11 CN3 9 CN3 8 CN3 1 CN3 2 CN3 3 CN3 4 CN6 2 CN6 3 CN3 10 CN3 12 BAS X4 1 X4 2 X4 3 X6 3 X6 1 X6 2 X8 20 X8 10 X7 8 X8 13 X8 14 X8 12 INTEGRATED CONTROL X8 5 X8 15 X7 7 X8 11 X8 6 X8 16 X8 7 X8 17 X8 1 T INLET SENSOR X8 3 X8 8 X8 2 X8 4 X8 9 X7 1 X7 5...

Page 14: ...0 5 X10 3 X10 6 X1 6 ON OFF SWITCH GND BK W PR T OR X6 18 X6 8 X1 8 G X6 9 X6 17 X2 4 X13 2 X13 3 BLOWER SMALL BLOWER LARGE R BK GY W W BK T M T GN R W BK W X2 3 X1 7 X1 10 X1 5 FLAME SENSE 2 FLAME SENSE 1 SPARK GENERATOR SPARK ROD X2 5 FLUE DAMPER TRANSFORMER X13 4 FLUE DAMPER 24V TRANSFORMER BL R R R P BK BL Y OR BL Y BK X1 2 X1 3 X1 1 INTEGRATED CONTROL LARGE CONNECTION BOARD SMALL CONNECTION B...

Page 15: ...0 10V 0 10V BMS IN SYSTEM PUMP IN SHIELD SHIELD A B CASCADE LARGE CONNECTION BOARD CN6 1 CN3 6 CN3 7 CN3 14 CN3 13 CN3 11 CN3 9 CN3 8 CN3 1 CN3 2 CN3 3 CN3 4 CN6 2 CN6 3 CN3 10 CN3 12 BAS X4 1 X4 2 X4 3 X6 3 X6 1 X6 2 X8 20 X8 10 X7 8 X8 13 X8 14 X8 12 INTEGRATED CONTROL X8 5 X8 15 X7 7 X8 11 X8 6 X8 16 X8 7 X8 17 X8 18 T INLET SENSOR X8 3 X8 8 X8 2 X8 4 X8 9 X7 1 X7 5 X7 2 X7 6 GROUND X6 18 X6 9 ...

Page 16: ... R O K B R O K B R O TEST SWITCH LWCO PROBE R O R O LWCO RESET X6 5 X6 15 BLOWER PROVING SWITCH LARGE R O X6 12 BLOWER PROVING SWITCH SMALL T X13 1 BLOCKED FLUE SWITCH R P X6 6 BLOCKED DRAIN SWITCH K B ENABLE X8 3 X8 8 X8 2 X8 4 X8 9 X7 1 X7 5 X7 2 X7 6 INLET SENSOR OUTLET SENSOR S9 OUTLET SENSOR S1 FLUE SENSOR FLUE SENSOR S10 PRE MIX SENSOR 1 S11 PRE MIX SENSOR 1 S13 PRE MIX SENSOR 2 S12 PRE MIX ...

Page 17: ...NSOR 0 10V 0 10V BMS IN SYSTEM PUMP IN SHIELD SHIELD A B CASCADE LARGE CONNECTION BOARD CN6 1 CN3 6 CN3 7 CN3 14 CN3 13 CN3 11 CN3 9 CN3 8 CN3 1 CN3 2 CN3 3 CN3 4 CN6 2 CN6 3 CN3 10 CN3 12 BAS X4 1 X4 2 X4 3 X6 3 X6 1 X6 2 X8 20 X8 10 X7 8 X8 13 X8 14 X8 12 INTEGRATED CONTROL X8 5 X8 15 X7 7 X8 11 X8 6 X8 16 X8 7 X8 17 X8 18 T INLET SENSOR X8 3 X8 8 X8 2 X8 4 X8 9 X7 1 X7 5 X7 2 X7 6 GROUND X6 18 ...

Page 18: ...Dual Fuel Supplemental Manual Notes 18 ...

Page 19: ...19 Dual Fuel Supplemental Manual Notes ...

Page 20: ...ts the update of wiring and ladder diagrams on pages 12 and 13 Revision C ECO C11685 reflects the addition of models 4 0 and 5 0 Revision D Change 500001029 reflects the removal of Models 1 5 and 2 0 along with updates to the control FBD SUP_MM 100161023_DIR 2000004585 Rev D 10 15 ...

Reviews: