 NOTICE

This is a gas appliance and should be 
installed by a licensed electrician and/or 
certified gas supplier.  Service must be 
performed by a qualified service installer, 
service agency or the gas supplier.

 WARNING

If the information in these instructions is 
not followed exactly, a fire or explosion 
may result causing property damage, 
personal injury, or death.

This appliance MUST NOT be 
installed in any location where gasoline 
or flammable vapors are likely to be 
present, unless the installation is such 
to eliminate the probable ignition of 
gasoline or flammable vapors.

What to do if you smell gas –

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any 
  phone in your building.

• Immediately call your gas supplier from a neighbors 
  phone.  Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire 
 department.

Installation and service must be performed by a qualified 
installer, service agency, or the gas supplier.

Warranty –

Factory warranty (shipped with unit) does not apply to 
units improperly installed or improperly operated.

Experience has shown that improper installation or system 
design, rather than faulty equipment, is the cause of most 
operating problems.

1.  Excessive water hardness causing a lime/scale build-up 
 

in the copper tube is not the fault of the equipment 

 

and is not covered under the manufacturer’s warranty 

 (see 

Water Treatment and Water Chemistry in the 

 

Copper-fin II Installation and Operation Manual

).

2.  Excessive pitting and erosion on the inside of the 
 

copper tube may be caused by too much water velocity 

 

through the tubes and is not covered by the 

 

manufacturer’s warranty (see 

Boiler Flow Rates and 

 

Temperature Rise for flow requirements in the Copper-fin 

 

II Installation and Operation Manual

).

Checking equipment –

Upon receiving equipment, check for signs of shipping 
damage.  Pay particular attention to parts accompanying the 
appliance which may show signs of being hit or otherwise 
being mishandled.  Verify total number of pieces shown on 
the packing slip with those actually received.  In case there is 
damage or a shortage, immediately notify the carrier.

Do not use this appliance if any part has been under water.  
The possible damage to a flooded appliance can be extensive 
and present numerous safety hazards.  Any appliance that 
has been under water must be replaced.

 WARNING

Improper installation, adjustment, 
alteration, service or maintenance can 
cause injury or property damage.  Refer 
to this manual for assistance or additional 
information, consult a qualified installer, 
service agency or the gas supplier.

 Owner warning –

The information contained in this manual is intended for use 
by qualified professional installers, service technicians, or gas 
suppliers.  

Consult your local expert for proper installation 

or service procedures.

 

NOTICE

Consult and follow all local Building and 
Fire Regulations and other Safety Codes that 
apply to this installation.  Consult a local gas 
utility company to authorize and inspect all 
gas and flue connections.

Your conventionally vented gas appliance must have a supply 
of fresh air circulating around it during burner operation for 
proper gas combustion and proper venting.

 WARNING

Should overheating occur or the gas supply 
fail to shut off, do not turn off or disconnect 
the electrical supply to the pump.  Instead, 
turn off the manual gas control valve to 
the appliance at a location external to the 
appliance.

Prevention of freezing –

Heat exchangers and headers damaged by freezing are not 
covered by warranty.

See Section 6, 

Startup -

 

Freeze Protection

 in the Copper-fin II 

Installation and Operation for more information.

                                  

User’s Information Manual

Summary of Contents for Copper-fin II 2072

Page 1: ...e present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a near by phone F...

Page 2: ...avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage Contents...

Page 3: ...nts in the Copper fin II Installation and Operation Manual Checking equipment Upon receiving equipment check for signs of shipping damage Pay particular attention to parts accompanying the appliance w...

Page 4: ...tal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building construc...

Page 5: ...stiff bristle brush Remove and clean burners using water Dry before re assembling Clean the blower wheel with a brush and vacuum Do not let dirt from cleaning get pulled into the blower Owner mainten...

Page 6: ...iquids near the appliance Remove immediately if found 2 Air contaminants Products containing chlorine or fluorine if allowed to contaminate the appliance intake air will cause acidic condensate in the...

Page 7: ...to a safe place of disposal This discharge line must be installed by a qualified heating installer or service technician in accordance with the instructions in the Copper fin II Installation and Opera...

Page 8: ...nformation above on this label 2 Turn off all electric power to the appliance 3 Open control access panel 4 This appliance is equipped with an ignition device which automatically lights the burner Do...

Page 9: ...nk water temperature set point during normal operation Press to change displayed data values in Menu Mode Press to navigate through menu listing in Menu Mode Press to toggle display during normal oper...

Page 10: ...the code parameter A1 must be accessed The default code is 0704 The code can be changed one digit at a time by using the arrow keys on the display A2 Date and time The control uses an internal clock...

Page 11: ...The maximum allowable tank set point can be adjusted using parameter E4 The temperature range of this parameter is 60 F 16 C to the value of parameter E3 to 190 F 88 C The default temperature is 190 F...

Page 12: ...in II Service Manual This feature can be turned on or off depending on the installation This parameter can be changed by the installer by accessing parameter G3 The control range of this parameter is...

Page 13: ...r ignition Display will show IGNITOR A or IGNITOR B depending on which stage has priority HTR RUN STG Or HTR DHW STG The unit has fired and is running at the displayed number of stages 1 2 3 4 HTR POS...

Page 14: ...parenthesis SYSSUP F If the system supply sensor has not been selected as the control sensor only the system supply temperature will be displayed SYSSUP OPEN The control does not detect the system su...

Page 15: ...Press the Next arrow key on the SMART SYSTEM display to access Screen 8 Screen 8 Line 1 SYS PUMP The control will display either ON or OFF based upon system pump requirements upon demand for space hea...

Page 16: ...release Revision B ECO C11124 reflects the update of ignition timing information on page 13 Revision C PCP 3000021634 CN 500011858 reflects an update to the maintenance information on page 5 CFX CHX...

Reviews: