7-24
LOADRITE Sprint User manual
7.
APPENDIX B: SPAN CALIBRATION
ADJUSTMENT
This function allows small changes to be made to the LOADRITE Weighing System calibration if the bucket is modified, or if no
accurate test weight was available when the LOADRITE Weighing System was calibrated at installation time.
The adjustment is carried out by entering the total weight recorded at a weighbridge (scale house) and the corresponding total
provided by the LOADRITE Indicator.
To perform the adjustment, a security access code must be obtained from your LOADRITE installer.
CAUTION
The LOADRITE Weighing System alters its calibration every time this function is used. It is important that this
function is only used once with a given set of data. If the same weights are entered again, the LOADRITE Weighing System will
over-correct and its accuracy will be seriously impaired.
1) Press
.
2) Select
Setup...
, then press
.
3) Enter the security access code provided by the LOADRITE installer, then press
.
4) Select
Calibration Menu
, then press
.
The
Calibration Menu
will display.
5) Select
Adjust Span
, then press
.
6) The
Adjust Span
message will display briefly and then the
LOADRITE Adjust Span
screen will display.
7) Enter the total weight provided by the LOADRITE Indicator, then press
.
8) Enter the total weight provided by the weighbridge, then press
.
9) The LOADRITE Indicator briefly displays the
Calibration Updated
message, and then returns to the
Calibration Menu
.