background image

American Spa Owner’s Manual

LTR50001143, Rev. R

Cleaning and Maintenance

26

Draining Your Portable Spa

1.  Turn off the power at the breaker.
2. 

Remove all filters.

3.  Using a Phillips screwdriver, remove the screws to 

the access panel and open it.

4.  Locate  hose  ending  with  the  ¾  inch  hose-bib 

fixture.

5.  Unscrew the cap.
6.  Hook up the female end of a garden hose to the 

drain fitting.

7.  Place the other end of the garden hose where you 

would like the water to drain to.

8. 

Turn the valve on the hose-bib fixture to open the 

drain.

9.  Let  spa  drain  completely,  then  remove  garden 

hose.

10. 

Turn the valve on the hose-bib fixture to close the 

drain.

11. Replace the cap.

Winterizing (Cold Climate Draining)

In many areas of the country, the temperature drops below 32˚F (0°C). We recommend that you always have 

your spa full of water and running at normal spa temperatures (80˚F to 100˚F, 26.7°C to 37.8°C). This will help 

reduce the risk of freezing in your spa and your spa’s equipment.

Warning: If you find the need to drain your spa, be aware of the potential of freezing in your 

spas equipment and plumbing. Even if the directions below are followed perfectly, there is no 

guarantee that your spa will not suffer freeze damage. Freeze damage is not covered by your 

warranty.

1. 

Open all filter covers.

2. 

Remove the filter baskets and filters.

3.  Drain  your  spa  completely  as  described  in  the 

instructions above.

4. 

Vacuum  water  from  the  spa’s  main  drain  fitting 

with a wet/dry vacuum.

5.  Open the bleeder valves on the pumps.
6. 

For spas with the UV lamp chamber mounted flat 

on the equipment floor:

Loosen the quartz tube nut at the top of the UV 

lamp chamber and pull up the quartz tube to let 

the water drain from the UV lamp chamber.

7.  Disconnect  the  unions  from  both  sides  of  the 

pump.

8.  Blow  any  remaining  water  out  of  the  jets  and 

equipment area with the wet/dry vacuum.

9. 

When it has completely finished draining, replace 

the  quartz  tube  in  the  UV  lamp  chamber  and 

retighten  the  nut.  Close  the  bleeder  valves  and 

re-connect the unions on the pumps. Replace the 

filter baskets and filters.

10. Cover your spa with a good spa cover and an all-

weather tarp to ensure that neither rain nor snow 

enters the spa.

Summary of Contents for AM-511RS

Page 1: ...LTR50001143 Rev R 8 8 17...

Page 2: ...FCI Wiring Diagram 6 NEO Wiring Diagram 7 Filling and Powering Up Your Portable Spa 8 Priming the Pump 11 Operating Your Spa 12 Electronic Control Operation 12 Jets 17 Water Diverters 17 Air Control 1...

Page 3: ...ater can induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level 3 F to 6 F above the normal body temperature of 98 6 F or 2 C to 4 C above 37 C While hyperth...

Page 4: ...should not use a spa or hot tub WARNING To avoid injury exercise care when entering or exiting the spa or hot tub WARNING Do not use drugs or alcohol before or during the use of a spa or hot tub to av...

Page 5: ...use it for relaxation and therapy you will probably want to create a specific mood around it If you live in a region where it snows in the winter or rains frequently place the spa near a house entry...

Page 6: ...ommend that a qualified licensed contractor prepare the foundation for your spa If you are installing the spa indoors pay close attention to the flooring beneath it Choose flooring that will not be da...

Page 7: ...Always follow applicable local state and federal codes and guidelines Use only a dedicated electrical line with a 15 amp breaker Cord and plug connections may not use a cord longer than 15 feet 4 6 m...

Page 8: ...American Spa Owner s Manual LTR50001143 Rev R Preparing for Your New Portable Spa 6 GFCI Wiring Diagram...

Page 9: ...American Spa Owner s Manual LTR50001143 Rev R Preparing for Your New Portable Spa 7 NEO Wiring Diagram...

Page 10: ...e filtration system which can cause the pump to fail to prime After the spa has been placed on an approved surface and has been correctly wired by a licensed electrician inspect all plumbing connectio...

Page 11: ...et Starting Up Priming Mode for Neo Pack Systems The system will enter the priming mode Priming Mode will display on the control panel In Priming Mode all devices such as jets and lights are operable...

Page 12: ...e sure the filter has soaked at least 30 minutes before you install it 7 Adjust water chemistry Test and adjust the water chemistry See the section on page 19 for instructions on water clarity 8 Let t...

Page 13: ...cond method will remove a large air lock within the pump 1 Using a Phillips screwdriver remove the front panel from the spa and locate the pump 2 While the spa is operating turn the bleeder valve coun...

Page 14: ...American Spa Owner s Manual LTR50001143 Rev R Operating Your Spa 12 NEO one pump system NEO two pump system Operating Your Spa Electronic Control Operation...

Page 15: ...American Spa Owner s Manual LTR50001143 Rev R Operating Your Spa 13...

Page 16: ...American Spa Owner s Manual LTR50001143 Rev R Operating Your Spa 14 F F F F A...

Page 17: ...American Spa Owner s Manual LTR50001143 Rev R Operating Your Spa 15 Settings Screens...

Page 18: ...American Spa Owner s Manual LTR50001143 Rev R Operating Your Spa 16 Error Screens...

Page 19: ...ckwise to increase clockwise to decrease Water Diverters Water diverter knobs are 1 and 2 knobs located around the top of your spa They allow you to divert water through jets from one side of the spa...

Page 20: ...ur spa may include two to eight streamer waterfalls When the booster pump is on turn the 1 diverter knob to adjust the rate of flow to the waterfall jets The waterfall jet faces are not adjustable Do...

Page 21: ...equat Met prate er sit dolor iriureetuer si Feummy nullamcore magna ad dio er sequamconum nis eu feugiamet vent et wisis ero dolore dip exeraestie estie vel inisci elisl ut diat cons aut alit lut lore...

Page 22: ...end to be too high and may be difficult to bring down High TA can be corrected by adding an alkalinity decreaser When the TA is balanced it normally remains stable although adding water with high or l...

Page 23: ...st strip or a reagent kit See the table on the following page for the ideal range Add one or two tablespoons granulated chlorine to the spa water weekly Note that chlorine dissipation rate will be fas...

Page 24: ...next higher filtration number then if water quality is still not adequate consult the advice of your Cal Spas dealer for additional chemical or system recommendations Be sure to give them your bather...

Page 25: ...ssary If your water source is high in calcium add stain and scale preventer Once a month Deep clean your spa s filter Follow filter cleaning instruction at beginning of this section Every two to four...

Page 26: ...ound spa Buildup of oils and dirt Wipe off scum with clean rag if severe drain the spa use a spa surface and tile cleaner to remove the scum and refill the spa Algae Growth High pH Low sanitizer level...

Page 27: ...into the holes Important Keep the spa covered when not in use Covered spas will use less electricity in maintaining your set temperature Covering your spa will protect your spa s finish from the sun s...

Page 28: ...ed to drain your spa be aware of the potential of freezing in your spas equipment and plumbing Even if the directions below are followed perfectly there is no guarantee that your spa will not suffer f...

Page 29: ...ions on page 15 for changing modes 2 Following the water quality instructions starting on page 19 adjust the pH 3 Shock the water add either chlorine or bromine sanitizer 4 When you return check and a...

Page 30: ...ted with common automotive vinyl protectants Warning Do not use automotive vinyl protectants on spa covers or pillows These products are generally oil based and will cause severe water clarity issues...

Page 31: ...the spa cabinet Everything can be done with your device The example shown below is from an iPhone device Your device may appear differently Before you begin make sure Bluetooth in enabled on your dev...

Page 32: ...light green purple light blue yellow etc Each time you press the button you immediately advance to the next color in sequence or eventually a different light pattern 2 Flashing When you are cycling th...

Page 33: ...SQN halo 2 neck jet 100 shut off Halo w graphite gray center PLU29520 611 500 SQ2D 2 euro jet directional Halo w graphite gray eyeball PLU29520 011 500 SQ3D 3 directional mini jet Halo w graphite eyeb...

Page 34: ...s Water Diverter Valves Diverter Valve 2 Star Fire Textured Black PLU21300468 Diverter Valve 1 Star Fire Textured Black PLU21300469 Air Control Valve Air Control Valve Star Fire Black PLU21300526 Snap...

Page 35: ...ll Curved Black Textured with Valve PLU21800826TEX Hydro Stream Waterfall Flush Mount Special Black 210 9201 13 PLU21800624 Aqua Rail 12 LED Blk Clear FIX25262 014 000 Drain Super Hi Flow suction Dark...

Page 36: ...ray COV7484B42G CC 2 84 x 84 AM 740B Basic Slate COV8484B42S WN 2 84 x 84 AM 740L Basic Slate COV8484B42S WN 2 84 x 84 AM 756BS Basic Slate COV8484B42S WN 2 84 x 84 AM 756LS Basic Slate COV8484B42S WN...

Page 37: ...American Spa Owner s Manual LTR50001143 Rev R Appendix 35 Spa Cover Lock and Key ACC01800020 Pillows Counter Lounge Pillow ACC01401500NL...

Page 38: ...spa Contact your dealer Heat Problems Spa does not heat Heating mode not selected See control panel instructions on page 12 Water level is too low Add water to correct level No electrical power to sp...

Page 39: ...d empty the hoses Close or turn off empty cycle if necessary Water Pressure Problems Jets surge on and off Water level is too low Add water to normal level Jets are weaker than normal or do not work a...

Page 40: ...act your dealer Pump turns off during operation Automatic timer has completed its cycle Start the cycle again Pump has overheated due to the vents on the equipment door being blocked Clear items away...

Page 41: ...ials Normal wear and weathering of the finish will occur naturally over time and are not defects LIMITED WARRANTY YEAR LIMITED W WA AR RR 1 Y Y Y R RA R R RA A T T TY Y Y A A AN NT T A A AN N N NT T T...

Page 42: ...his Limited Warranty does not provide coverage for the insulating cover any item attached to or installed on the spa after the date of manufacture or for gaining access to any component for repair or...

Page 43: ...American Spa Owner s Manual LTR50001143 Rev R Appendix 41...

Page 44: ...________________________ Date Installed _________________________________________________________________________ Dealer s Phone Number ________________________________________________________________...

Reviews: