![Lloyd's LC-1342 Quick Installation Manual Download Page 25](http://html1.mh-extra.com/html/lloyds/lc-1342/lc-1342_quick-installation-manual_1932010025.webp)
25
Static current:
Dynamic current:
Administrator capacity:
User capacity:
Fingerprint sensor:
Fingerprint identification angle:
False rejection rate:
False recognition rate:
Reaction time:
Emergency power:
Operating temperature:
Relative humidity:
Voice assistant:
Keyboard:
Numeric code length:
Password camouflage:
Low battery alarm:
Unlocking time:
≤ 50 uA
≤ 250 mA
9 (from 1 to 9)
Supports nine administrators and 291 regular
users (opening with fingerprints and numeric
passwords)
semiconductor
360°
≤ 0,1%
≤ 0,00004%
≤ 0,1 seconds
5 Vdc
14° F ~ 140° F (-10 °C ~ 60 °C)
20% to 93% RH
Yes
Touch standard 12-bit keyboard
6-8 digits
20 digits
4.8 ± 0,2 Vdc
≤ 1 second
4.
Technical parameters
5.
Installing considerations
It is advisable to search for qualified personnel for the installation. Read this manual carefully before
installation.
Don’t press or fold the connecting cable during the installation.
Before installation, verify that the thickness of your door is compatible with the specifications of
the product.
During installation, the door must be half open.
Once the installation is complete, verify that the fingerprint, the numeric password (followed by
“#”), the app, and the key work properly to release the lock. If they don’t work, verify that the con-
nection is correct and that the power cable is not loose.
1
2
3
4
5