Installation:
LKK Commercial Gas Stockpot are to be installed by a certi
fi
ed gas technician.
Technical Speci
fi
cations:
The appliance installation must comply with the installation & ventilation requirements of AS/NZS5601.1,
Australian Standard, “Gas Installations” any local Authority regulation and the Manufacturer’s installation
instructions.
Warning:
Do not install LKK Gas Stockpot in marine environment. Some examples include on a boat or
outdoor in the sea breeze. Doing so will result in unnecessary rust.
Remove all packaging prior to installation including the stainless steel plastic
fi
lm if any.
Inlet Connections:
Gas ¾” (20mm ¾ BSP) galvanised pipe threaded to individual holes
Use of Flexible Hoses:
Where it is intended to connect the appliance to the gas supply using a
fl
exible, it is important to use the
correct type assembly for the application. Refer to AS/NZS5601 for hose connection requirements. The hose
assembly must comply with AS/NZS1869 – Class B 20mm (¾”) diameter minimum, and be kept as short as
possible. A chain must be
fi
tted to restrict the appliance movement to no more than 80% of the hose length.
Appliance Gas Regulator:
An appliance gas pressure regulator must be
fi
tted for Natural gas and LPG appliances.
Refer AS4563 – Commercial Gas Catering Equipment (implementation Jan 2005)
Fit an appliance isolating valve before the inlet. This must be a ¼ turn type, be approved and be in an
accessible location when the appliance is installed and working.
A regulator is supplied with the unit for each burner: Maxitrol, RV48 AGA#3088 (Natural Gas)
Maxitrol, RV48 AGA#3088 (L.P.G)
Regulator must be checked and adjusted to the correct working pressure using a digital manometer after
installation. Skipping this step will compromise the stockpot burners performance.
Note:
Never reuse an old regulator with a new appliance.
Commissioning:
Each burner
fi
tted with a regulator must be adjusted to the correct working pressure upon installation.
Refer to dataplate.
After Installation:
Before leaving installation check all gas and water
fi
ttings for leaks, and instruct the operator in the lighting
procedure and use of appliance.
If unit fails to operate contact local distributor or call manufacturer.
Any of the following are deemed to be abnormal:
1. Burners burning with a yellow soft
fl
ame
2. Sooting of pots, pans and woks
3. Unusual odours being emitted when appliance is operating
Contact LKK or an authorised service agent if any of the above is present.