Assembly instructions | LK WSS Mini
EN.40.C.11.2021-01-22
Guarantee
LK Systems AB is responsible for faults in prod-
ucts that appear within two years from the deliv-
ery of the product to the buyer. If LK is responsi-
ble for the fault in the product, LK has the right to
replace the product with either a new or repaired
product. The liability period for replacement or
repair of a product or spare part does not exceed
the liability period for the original product. The
seller is not responsible for faults resulting from
accidents, incorrect assembly, incorrect installa-
tion, incorrect care, abuse or other irregular use.
LK Systems AB is not responsible for any loss or
damage caused by a non-functioning product.
Its responsibility is strictly limited to the replace-
ment of the product.
System approval
LK Water Safety System WSS is tested and ap-
proved in accordance with SINTEF Technical Ap-
proval No. 20598.
Technical data
Master unit
Operated with 5V 0.2A DC.
Contact for connected sensor: 3.5 mm.
Radio frequency: 433 MHz, bi-directional.
Temperature measurement: -10 - 55 °C.
2 x LK electric valves can be connected.
Dimensions: 137 x 62 x 28 mm.
Control panel
Operated with 2 x AA alkaline batteries or 5-18V, 100 mA DC.
Radio frequency: 433 MHz, bidirectional.
Temperature measurement: -10 - 55 °C.
3 x buttons with 6 x alarm indicators.
Dimensions: 85 x 85 x 20 mm.
Leak detector
Power supply 2 x AA alkaline batteries or 5V 100 mA DC.
Contact for sensor connection: 3.5 mm. Radio frequency: 433
MHz, bi-directional.
Temperature measurement: -10 - 55 °C.
DIP switch to shut o
ff
the temperature alarm.
2 x diodes for alarm indication and one buzzer.
Dimensions: 137 x 62 x 28 mm.
Electric valve
Pressure range: 0-10 bar.
Temperature range: 0-80 °C.
Connection: G15, G20 or G25. Power supply: 5V DC.
Material: stainless steel SS304.
Cable with snap connector
fi
tted.
433 MHz
Comment
Completely trouble-free operation cannot always
be guaranteed with the currently technology
available that allows free use of the frequency
band. Every installation should therefore be test-
ed individually.
Environment
LK Systems is affi liated with El-Kretsen for col-
lecting and recycling electronics and batteries.
Used batteries should be sorted as batteries or
small batteries and deposited for battery recy-
cling. When the system has reached the end of
its life, it should be sorted as electronics or other
electronics and deposited with a recycling centre.
6 (7)