background image

1 (3)

Installation

Note! LK Heater 350 should only be moun-

ted together with the LK Minishunt M60n.

The control unit is mounted in direct proximity to 

the Minishunt installation. Fix the electrical cables 

to the heater plus other cables in the near surroun-

ding to ensure that no cables can come in contact 

with the housing of the heater brass tube. Mount 

the supplied safety valve in the Minishunt outlet 

according to the image below. The safety valve is 

fitted with a self-sealing O-ring. The safety valve 

also has a so called metallic seal which can make 

it seem as if the valve is ”slow” to install. 

Ensure that the inflow sensor is located in the 

brass tube’s well pockets. The sensor should be 

clamped with the clamping screw. 

Note! The inflow sensor should always be 

installed and connected during operation.

Design

LK Heater 350 is an electric comfort heater 

for floor heating installations performed with  

LK Minishunt M60n. LK Heater 350 makes it pos-

sible to have warm floors in the summertime in 

single rooms (for example bathrooms) when the 

house’s regular heat source is turned off. When 

the heating season starts the electric comfort hea-

ter shall be turned off and the area is heated by 

the house’s regular heat source. 

The heater consists of an electric cartridge instal-

led in a brass tube. The electric cartridge is con-

trolled by an electronic controller for the constant 

regulation of the water temperature. The product 

is sold complete for 1 or 2 heating circuits in 12 

or 16 mm pipe dimensions. The electric cartridge 

power is 350W and is sufficient under normal 

conditions for floor heating surfaces up to 12 m

2

.

The image shows the components to LK Heater 350 for two 

heating circuits. In the image LK Heater is assembled to 

LK Minishunt M60n which is shaded in the picture. 

Function

On the controller the max water inflow tempera-

ture can be set up, from 22 ºC to 35 ºC. 

The LK Heater can also be put in frost protection 

mode with an adjustable water temperature to 10 ºC.  

Key down the temperature setting to 22 ºC, and 

press one more time so that the light for 22 ºC flashes 

indicating frost mode, 10 ºC water temperature. 

LK Heater 350

EN.33.C.77.2002

Assembly instructions | LK Heater 350

Reviews: