Vertical Calibration:
It’s same as horizontal calibration.
The “printing test” includes also bi-direction test, step test, nozzle status and
test line. Among the rest, you can set the bi-direction test and step test as the
same way as the horizontal calibration. And fill in the calibration value into
the bi-direction test and step test items. Nozzle status tests if printhead is
clogged. Once the printhead is clogged, it will be represented by the nozzle
status testing image.
Test line is to test general status after calibration, such as horizontal, vertical,
step and bi-direction calibration etc. If any one of them is not set properly,
test lines will show it.
All these calibration data is saved in
Liyu.dat.
You can backup it for safety.
5.4 Print images
Click file
→
open or
icon on the toolbar, then choose a *.prt or *.prn
file to open. Then the preview of the file will appear in preview area on the
right side of the main interface. If it’s really the image you want, please click
file
→
print or
icon on the toolbar, the printer starts to print.