15

14

Instructions for Cleaning the Electrode Plates

• To insure continued optimum water ionization, it is necessary that you clean the C7 ionization engine (electrodes)

every 2850 gallons . This is accomplished using a cleaning cartridge that contains citric acid. Citric acid is a common

food additive that poses no health risks.

• This cleaning process requires that you (1) remove the expired water filter (2) install the cleaning cartridge and (3)

briefly operate the C7 to introduce the citric acid into the ionization engine. The citric acid must remain in the

ionization engine for five (5) hours to insure complete cleaning.

• After the cleaning process is completed, you will install a new water filter and then you can again produce and enjoy

high quality ionized water.

• Disconnect the C7 power cord.

• Remove the water filter cover. Press the tab on the side of the cover. Swing the

cover on its hinges and remove it.

• Remove the old water filter cartridge by turning the filter cartridge counter

clockwise as far as it will go.

• Lift the cartridge out of its seat. It might require some slight “side-to-side”

movement to help loosen the cartridge.

• Install the cleaning cartridge. Insert the cleaning cartridge all the way into the

filter cartridge seat. Turn the cartridge clockwise until it will no longer turn.

• Insert the cork plug (provided with the cleaning cartridge) into end of the 3/8” gray acid water drain tubing (the tube

attached to the suction cup).

1.

• Position the ionized water delivery hose (attached to the top of the C7) so

that the spout on the end of the hose is HIGHER than the body of the C7.

Bend the end of the hose so that the spout is in a down position.

2.

• SLOWLY turn the water ON.

NOTE:

You may need to physically hold the lever on the faucet diverter valve in the out position as there may not be enough water

pressure to automatically keep the lever in the “on” position.

NOTE:

Hold a glass or cup under the spout to catch the water coming out of the hose.

Instructions for Cleaning the Electrode Plates, continued

• Adjust the water flow until there is a rapid sequence of drops coming out of the ionized water output hose.

• Let the water run (DRIP) for about ONE minute. This will insure that the ionization engine in full of cleaning fluid

(citric acid).

• Turn the water OFF. Let the C7 sit (unused) for 5 HOURS.

• After 5 hours has passed, remove the cork plug from the gray acid water drain tubing.

• Remove the cleaning cartridge. Turn the cleaning cartridge counter clockwise as far as it will go. Lift the cartridge out

of its seat.

• Discard the cartridge (the cartridge is designed to be used only once).

• Reinstall the filter or replace the filter if needed. Insert the filter cartridge

all the way into the filter cartridge seat. Turn the cartridge clockwise until

it will no longer turn.

• Replace the filter cartridge cover. Position the taps on the cover into the

slots on the body of the C7. Close the cover, securing the plastic latch.

• Reposition the ionized water output hose (on top of the C7) so that is

again pointing into the sink.

3.

• Reconnect the C7 power cord

• Turn the COLD water on FULL. Pull out the faucet diverter valve PIN to route water to the C7. Let water run through

the water ionizer for 3 minutes. This will fill the new filter with water and flush out any residue citric acid from the

ionization engine.

• RECHECK the water flow rate through the C7. Adjust the water flow (ball) valve (located between the faucet head

diverted and the C7 water IN connector) so that the water flow rate on the LCD display reads somewhere 2.3 and 2.8

liters/minute.

• Reset the filter life count if you replaced the filter with a new one.

1.

2.

3.

Summary of Contents for ESSENTIAL C7

Page 1: ...tments LLC 300 East Valley Drive Bristol VA 24201 800 989 2299 OWNER S MANUAL C7 MODEL WATER IONIZER CAUTION Read manual carefully for proper procedures and operation EA 03207 2009 DBG Group Investments LLC All rights reserved ...

Page 2: ...ng codes can result in leaks and or water damage and will void your warranty We expressly disclaim any liability for damage caused by leaks and or other water damage Chlorine and pH Test Reagents Do not expose the pH or chlorine test reagents to extreme heat or flames They are combustible Store in a cool dry location Keep the reagents tightly sealed and store out of the reach of children Do not dr...

Page 3: ...daches rashes diarrhea and or nausea You may notice differences in bowel habits during the first days at each pH level Urine frequency may increase and color may darken as more water is consumed and your body detoxifies Eventually the color decreases as your body adjusts to the cleansing If detoxification symptoms become uncomfortable it is suggested that you decrease to a lower level alkaline wat...

Page 4: ...electrician if you are not sure whether the electrical outlet you intend to use is properly installed Do not modify the electrical power cord or plug provided with the water ionizer and do not use a three prong to two prong adapter Improper grounding can result in risk of electric shock as well as damage to the water ionizer Do not plug the water ionizer into an electrical outlet that will result ...

Page 5: ...he quick connect connectors will swivel to accommodate exit from either side Place the water ionizer in an upright position Faucet Diverter Installation Remove the aerator from the faucet head Put this in a location where you can find it if you ever need to reinstall it onto the faucet at a later date This is usually done without tools by rotating counter clockwise 1 Slip on the rubber sealing rin...

Page 6: ...he use of the Super Charger Filter optional High alkaline water is excellent for cleaning NOTE Please note that after you turn off the water the LCD display will automatically turn off the light one minute later The pH selection button light will remain on PH ORP LIFE 8 5 160 mv 12000L FLOW DRINKING 3 4 L m FLOW DRINKING 3 4 L m PH ORP LIFE 8 5 160 mv 12000L Electrode clean 3 4 L m FLOW Electrode ...

Page 7: ...he filter when the Filter Replacement Indicator glows red The LCD screen will flash red as well The light on the indicator will glow once approximately 10 000L of water has passed through the ionizer Citric acid cleaning cartridge is needed for proper cleaning every 2850 Liters WARNING Replace the filter immediately If the following events occur Water has a very bad smell Unit has been unused for ...

Page 8: ...sically hold the lever on the faucet diverter valve in the out position as there may not be enough water pressure to automatically keep the lever in the on position NOTE Hold a glass or cup under the spout to catch the water coming out of the hose Instructions for Cleaning the Electrode Plates continued Adjust the water flow until there is a rapid sequence of drops coming out of the ionized water ...

Page 9: ...ked or bent restrictions Replace with new filter pg 13 Straighten hose Open inlet valve completely Replace with new filter pg 13 or use a sulphur pre filter Use a citric acid cleaning cartridge Filter needs replacing or water is too strong Drink on lower setting Contact your Dealer Reset filter life see pg 13 Plug unit into power source Test electrical outlet or call your electrician Turn on the f...

Page 10: ...sotherthanthose providedbyourauthorizedServiceCenter Thiswarrantydoesnotcoveranywaterdamage EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY DISCLAIMED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE LIMITATION OF LIA...

Reviews: