LCD Display
When you select a pH level of water, the LCD display will flash within 2 seconds. The first screen
indicates the pH/ORP of the water. The second screen shows the water flow.
* pH and ORP values displayed may not represent actual values.
Acidic:
Acidic water is a pH level of 5.5, however a pH level as low as 2.6 can be achieved if the Super Charger
Filter (optional) is utilized. This water is an astringent. This is not drinking water.
Filtered Water:
Neutral water is a pH level of 7.0. This water should be used when taking medicines or with baby
formula.
Alkaline 1:
Alkaline 1 is a pH level of 8.5. Begin drinking water from this level for the first week, gradually
increasing your consumption.
Alkaline 2:
Alkaline 2 is a pH level of 9.0. Drink water from this level once you are adjusted to
Alkaline 1, gradually increasing your consumption.
Alkaline 3
:
Alkaline 3 is a pH level of 9.5. Drink water from this level once you are adjusted to
Alkaline 2, gradually increasing your consumption. This is the ideal setting once the body has adjusted
to alkaline water. In the fourth week and thereafter, use this water for drinking, cooking, coffee and tea.
Alkaline 4
:
Alkaline 4 is a pH level of 10.0, however a higher pH level up to 11.4 can be achieved with the use of the
Super Charger Filter (optional). High alkaline water is excellent for cleaning.
NOTE:
Please note that after you turn off the water, the LCD display will automatically turn off the light one minute later. The pH
selection button light will remain on.
PH
ORP
LIFE
8.5
-160 mv
12000L
FLOW
DRINKING
3.4 L/m
FLOW
DRINKING
3.4 L/m
PH
ORP
LIFE
8.5
-160 mv
12000L
Electrode clean
3.4 L/m
FLOW
Electrode clean
3.4 L/m
FLOW
Electrode clean
3.4 L/m
FLOW
Automatic Electrode Cleaning
• Your water ionizer has an automatic electrode cleaning feature built in that reverses water flow across the electrodes
keeping the system operating at peak efficiency. The system is programmed to enter the automatic cleaning mode after
each 40 Liters of ionized water is produced. After 2850 Liters, the unit requires use of a citric acid cleaning cartridge to
clean the system properly.
• While in the automatic cleaning cycle, the LCD background will illuminate RED and an audible beeping sound is heard
from the machine. The automatic cleaning cycle is short, only requiring one liter of water to clean the electrodes.
• The LCD screen will display the following during the cleaning cycle.
After the cleaning cycle is complete, alkaline and acid water is available for use.
11
LCD display
Filter replacement
indicator
Function selection
Alkaline water
(4 pH
selections)
Filter reset
Increase
Setting
Decrease
Filtered water
(neutral pH
level)
Acidic water
10
OPERATION
Control Panel