  Do not use mineral water in the nebulizer for nebulizing purposes. 

  Always dispose of any remaining medication in the medication tank after each use. 

Use fresh medication each time you use the device. 

  Do not leave the device or its parts where it will be exposed to extreme tempera-

tures or changes in humidity, such as leaving the device in a vehicle during warm or hot 
months, or where it will be exposed to direct sunlight. 

CAUTION

 

  Limit the use of the device to 20 minutes at a time, and wait 40 minutes before using the 

device again. 

  Provide close supervision when this device is used by, on, or near infants, children or 

compromised individuals.

  Do not insert any object into the compressor. 

  Make sure that the air 

fi

 lter is clean. If the air 

fi

 lter has changed color or has not been 

used for 60 days, replace the 

fi

 lter. 

  Make sure that the nebulizer kit is correctly assembled, the air 

fi

 lter is properly installed, 

and the air tube is correctly connected to the compressor and the nebulizer kit. Air may 
leak from the air tube during use if not securely connected. 

  Inspect the compressor (main unit) and the nebulizer parts each time before using the 

device. Make sure no parts are damaged, the nozzle and air tube are not blocked and 
the compressor operates normally. 

  Do not use the device if the air tube is bent.

  Do not block the air 

fi

 lter cover. 

  Do not alter the baf

fl

 e, the nozzle in the medication tank or any part of the nebulizer kit. 

  Do not add more than 10ml of medication to the medication tank. 

  Do not operate the device at temperatures greater than 40

˚

C. 

  Do not tilt the nebulizer kit so the angle of the kit is greater than 45

˚

. Medication may 

fl

 ow into 

the mouth. 

  Do not shake the nebulizer kit while using the device. 

  Do not subject the compressor, or any of the components to strong shocks, such as 

dropping on the 

fl

 oor. 

  This device is approved for human use only. 

  Do not disassemble or attempt to repair the device or components. 

  Use the device only for its intended use as described in the instruction manual. Do not 

use attachments not recommended by the manufacturer.

  Dispose of the device, components and optional accessories according to applicable 

local regulations. Unlawful disposal may cause environmental pollution. 

  Make sure that the air tube is securely attached to the compressor (main unit) and 

nebulizing parts, and does not come loose. Twist the air tube slightly when inserting it 
into the connectors to avoid the tube disconnecting during use. 

RISK OF ELECTRICAL SHOCK

  Do not use the compressor (main unit) and the power cord while they are wet. 

  Do not plug or unplug the power cord into the electrical outlet with wet hands. 

  Do not immerse the compressor (main unit) in water or other liquid. 

Summary of Contents for LD-221C

Page 1: ...LD 221 Compressor Nebulizer LD Instruction Manual LD ENG RUS...

Page 2: ...ENG 16 PARTS AND COMPONENTS LD 221C...

Page 3: ...llow LD N001 Inhalation baffle mainly the lower respiratory tract Consist of two parts cone and cylinder Expendable material 9 3 Baffle C Red LD N003 Inhalation baffle mainly the upper respiratory tra...

Page 4: ...n solution residual volume and reliable and simple use We thank you for your choice GENERAL INFORMATION Compressor nebulizer LD is designed for treating the diseases of respiratory passages and lungs...

Page 5: ...ates normally Do not use the device if the air tube is bent Do not block the air filter cover Do not alter the baffle the nozzle in the medication tank or any part of the nebulizer kit Do not add more...

Page 6: ...NTENANCE AND STORAGE Keep the device out of the reach of unsupervised infants and children The device may contain small parts that can be swallowed Do not leave the cleaning solution in the nebulizer...

Page 7: ...e first time it is nec essary to make a full cleaning as described in last paragraph SAFETY INFORMATION 1 Place the nebulizer in front of you on the table Make sure the device is turned off power swit...

Page 8: ...of baffle the particles of different sizes are dis tributed aerosols as follows particle sizes mkm to the total mass 0 5 10 15 1 100 60 30 10 7 5 3 mainly the upper respiratory tract Dispenser C red D...

Page 9: ...on and reducing aerosol loss when exhaling The effec tiveness of inhalation using the breath actuated nebulizer is increased significantly INHALE EXHALE Completing the inhalation When the inhalation s...

Page 10: ...mask LD N040 1 9 Inhalation tube LD N051 1 10 Adult nasal nozzle LD N058 1 11 Child nasal nozzle LD N059 1 12 Inhalation filter LD N055 5 13 Instruction Manual 1 14 Warranty Card 1 15 Packaging 1 16...

Page 11: ...Net Weight no more 1400 g Protection against electric shock type BF Measured by Little Doctor International S Pte Ltd SYMBOLS CE marking in conformity with EC directive 93 42 EEC Important Read the ma...

Page 12: ...TATE REGISTRATION This device manufacturing is certified according to international standard ISO 13485 Device comply with the requirements of European Directive MDD 93 42 interna tional standards EN 1...

Page 13: ...ENG 27 Authorized Representative in the EU Little Doctor Europe Sp z o o 57G Zawila Street Krakow 30 390 Poland...

Page 14: ...I584 2101 09 Little Doctor International S Pte Ltd Little Doctor International S Pte Ltd 2020 UA TR 001 WWW LITTLEDOCTOR SG...