background image

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

· 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/

abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and 

all fixture labels.  

· 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general 

precautions.

· 

Installation and service of luminaires should be performed by a qualified licensed electrician. 

· 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and 

operation and any hazards involved.  Regular fixture maintenance programs are recommended. 

· 

It will occasionally be necessary to clean the outside of the refractor/lens.  Frequency of cleaning will depend on 

ambient dirt level and minimum light output which is acceptable to user.  Refractor/lens should be washed in a 

solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.  

Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing 

damaged gaskets as necessary. 

· 

DO NOT INSTALL DAMAGED PRODUCT!  This luminaire has been properly packed so that no parts should have 

been damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should 

be replaced.

· 

Recycle: For information on how to recycle LED electronic products, please visit 

www.epa.gov

· 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible 
contingency to meet in connection with installation, operation, or maintenance.  Should further information 
be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s 
purposes, this matter should be referred to Acuity Brands Lighting, Inc. 

 

Disconnect or turn off power before installation or 

servicing.

 

Verify that supply voltage is correct by comparing it with 

the luminaire label information.

 

Make all electrical and grounded connections in 

accordance with the National Electrical Code (NEC) and 

any applicable local code requirements.

 

All wiring connections should be capped with UL 

approved recognized wire connectors.

WARNING

RISK OF ELECTRIC SHOCK

 

Allow lamp/fixture to cool before handling. Do not 

touch enclosure or light source.

 

Do not exceed maximum wattage marked on 

luminaire label. 

 

Follow all manufacturer’s warnings, recommendations 

and restrictions for: driver type, burning position, 

mounting locations/methods, replacement and 

recycling.   

WARNING

RISK OF BURN

CAUTION

RISK OF FIRE

 

Keep combustible and other materials that can burn, 

away from lamp/lens.  

 

Do not operate in close proximity to persons, 

combustible materials or substances affected by heat 

or drying. 

CAUTION

RISK OF INJURY

 

Wear gloves and safety glasses at all times when 

removing luminaire from carton, installing, servicing or 

performing maintenance.

 

Avoid direct eye exposure to the light source while it is on.

Summary of Contents for RSX1 LED P4

Page 1: ...laced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for t...

Page 2: ...uminaire that are not factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation LED fixtures must be powered directly off a switched circuit Unless individual product specifications deem otherwise Do not restrict fixture ventilation Allow for some volume of airspace around fixture Avoid covering LED fixtures with insulation foam or other material tha...

Page 3: ...ing Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Figure 2a Figure 2b Figure 2c Top Hole 1 Loosen two captive screws on cover of the SPA to access the pole mounting area See Figure 1 2 Two mounting bars are included in the installation kit a The shorter bar is used for 8 Lithonia drilling and has 3 holes The top and bottom hole are threaded b The lo...

Page 4: ...gh the arm slot and into the available threaded hole of the mounting bar See Figure 4 5 The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the pole on existing hole patterns Insert the wires through the clearance slot shown in Figure 5 and pull them into the pole 6 Ensure luminaire is straight level making sure that no wires are pinched tighten the two bol...

Page 5: ...RSX LED RSX MAST ARM ADAPTOR INSTALLATION Tools Required Socket wrenches 5 8 Allen wrench 5 16 Minimum tenon pole diameter 2 schedule 40 pipe 2 3 8 OD 1 Slip luminaire Mast Arm Mount over 2 3 8 Ø pole tenon See Figure 7a 2 Use provided set screws and secure the luminaire in required position 3 Use thru bolt hole provided as pilot and drill 1 2 Ø hole on tenon through mast arm from both side See Fi...

Page 6: ...of the rubber grommet pull them into the wire connection area Replace the rubber grommet back as originally assembled before wire feeding See Figure 8b 8c Figure 8a Figure 8b Figure 8c 2016 Acuity Brands Lighting Inc All Rights Reserved Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Part Number IN 379 Rev F Revision Date 11 19 18 Re...

Page 7: ...it Repeat this step for black hot and white neutral wires Select Wago connec tors with matching colored wires coming from SPD See Figure 9a 9b 9c Figure 9b Figure 9a Figure 9c 6 Use cable tie and tie all newly attached wires shown in Figure 10 7 Make sure that wires are not pinched the door gas ket did not move from original position and sits in its groove on the door properly Reinstall the mounti...

Page 8: ...Bolts while maintaining the correct position of the luminaire to 23 27 ft lbs 11 Energize the luminaire to verify its operation and proper illumination of area WARNING USE AND PROPERLY TIGHTEN THRU BOLT AND NUT FAILURE TO CORRECT LY INSTALL COULD RESULT IN SERIOUS INJURY OR DEATH 7 16 14 Bolt Set Bolts Pole Tenon Thru Bolt Hole Figure 11a Figure 11b 2016 Acuity Brands Lighting Inc All Rights Reser...

Page 9: ...d evenly tighten the six 6 3 8 16 UNC knuckle tenon set screws to 23 27 ft lbs while maintaining the correct position of the luminaire 3 Cut and splice the wires Recommended cut length is 6 for wires for ease of splicing and securing in the knuckle See Figure 12b 4 Make all wiring connections via the supplied wire leads in accordance with NEC and local codes 5 Push all fixture and supply wires com...

Page 10: ...lbs See Figure 12c 7 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted from 0 to 45 from horizontal per ANSI C136 10 2010 8 Energize the luminaire to verify its operation and proper illumination of area WARNING DO NOT MOUNT THE KNUCKLE FITTER TO A TENON OR BRACKET THAT IS MORE THAN 5 DEGREES FROM VERTICAL MOUNTING AT AN ANGLE GREATER THAN 5 DEGREES REQUIRE...

Page 11: ...five 5 3 8 16 UNC knuckle tenon set screws to 23 27 ft lbs while main taining the correct position of the luminaire 2 Use upper set screw hole on front face of the knuckle as pilot and drill 1 2 Ø hole on tenon through knuck le See Figure 13a 3 Insert 7 16 14 x 3 3 4 bolt through Knuckle and drilled 1 2 Ø hole on tenon Place 7 16 Center Lock Distorted Thread Locknut onto bolt and tighten se curely...

Page 12: ...ee Figure 13c 13d 9 Aim fixture as required and tighten the 7 16 14 SHC knuckle adjustment bolt using an approximately 38 ft lbs See Figure 13e 10 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted to 45 from horizontal per ANSI C136 10 2010 11 Energize the luminaire to verify its operation and proper illumination of area WARNING DO NOT MOUNT THE KNUCKLE FI...

Page 13: ...e 14a and secure to wall with secure base plate to wall with 4 1 4 diameter fasteners by others using the 4 holes located on the outer corners of the base plate Check the base plate to confirm that it is level and plumb in all directions See Figure 14b 3 Prepare the cover plate by ensuring the factory installed gasket is in place on the backside of the cover plate See Figure 15 4 Open up the light...

Page 14: ...s are not pinched and tuck excess wire up into the luminaire mounting area 9 Reinstall the SPA Cover that was removed in step 6 tighten the two captive screws with the 9 64 Allen wrench to 18 20 in lbs overtighten can cause thread stripping and void all warranties CAUTION THE NEXT STEPS WILL REQUIRE ASSISTANCE 10 Make all wiring connections via the supplied wire leads in accordance with NEC and lo...

Page 15: ...llation Figure 19 2 Use flat screw driver to turn FAO dial to get required Lumen output See Figure 20 See table for settings Table 1 Figure 20 FAO Adjustment Dial 2016 Acuity Brands Lighting Inc All Rights Reserved Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Part Number IN 379 Rev F Revision Date 11 19 18 ...

Page 16: ...8 8 312 40 000 Values are based on the highest performance package for each fixture size FAO device shipped set at maximum setting 8 Lumen values vary by optic type Table 1 2016 Acuity Brands Lighting Inc All Rights Reserved Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Part Number IN 379 Rev F Revision Date 11 19 18 3 Make sure th...