background image

page 3

INSTALLATION INSTRUCTIONS

20

°

 down below horizontal in order to prevent water from  

accumulating inside lens. 
After lamp heads are positioned as desired, align the optional 

visor (10) over the front of the round lamp head and secure by 

tightening the set screws (11) on the visor.

9. Turn on electricity at fuse or circuit breaker box and verify 

success of installation.

 Note: 

on models with photocell, adjust 

photocontrol cover so that the window is fully open. See Trouble 

shooing guide for more info.

10.  Apply silicone caulking 

(not included) around the perimeter 

moisture seal.

Check to    

ensure all parts are included. 

Note: 

Account for small parts and           

destroy packing material, as these may be hazardous to children.

2. Turn OFF Power at circuit breaker box.

    CAUTION: 

Do not rely on wall switch alone to turn off power. 

Note: 

Suitable for wall mount or eave mount.           

Not suitable for ground mount installation.

3. Install cross bar 

(4) to your junction box using two 3/4” #6 or #8 

or #10 screws (5) (screw size is depending on your junction box).

4. 

Hang one end of the 

support hook (12) 

onto the cross bar 

 

See Fig.B

CAUTION: WIRING AND FIXTURE OPERATION

Make sure power is turned off. Connect to 120V, 60Hz circuit only. 

use wire nut (6) to connect the (copper) 

Note: 

If house wiring does not include a ground wire, consult your local 

electrical code for approved grounding methods. 

For proper connection, place wire nut over wires

 and twist clockwise until tight.

6. To Connect supply wires 

use wire nut (6) to connect the black 

wire to the white (neutral) supply wire.

insert mounting screw (3) into center hole of 

with rubber plug (7). See Fig A. 

Note: 

make sure no wires are 

pinched before tightening.

8. Aim lamp heads and install optional visor (round heads)

Each lamphead can be positioned in multiple directions via 

the adjustment knob (9) and the lock nut (8). 

Note: 

Make sure 

to secure all lock nuts and adjustment knobs tightly (do not 

CAUTION - Risk of Shock: 

Aim lamp heads at least 

Figure A

1) LED Light Fixture

3) Mounting Screw

7) Rubber Plug

4) Cross Bar

5) 3/4” Screws

6) Wire Nuts

8) Lock Nut

FIXTURE PACKING LIST

Description

Quantity

 1) LED Light Fixture................................................................. 1

 2) Photocontrol with adjustable cover (PE model only) ........... 1

 3) 1-1/4”(2H)  & 2”(3H) Mounting Screw ................................. 1

 4) Cross Bar ............................................................................ 1

 5) 3/4” #8 & #6 & #10 screws* ................................................. 6

 6) Wire Nuts* ........................................................................... 3

 7) Rubber Plug* ....................................................................... 1

 8) Lock Nut ................................................................2 or 3 or 4

 9) Adjustment Knob ..........................................................2 or 3

10) Visor (Round Head only) .............................................2 or 3

11) Set Screw (Round Head only) .....................................4 or 6

12) Support Hook* .................................................................... 1

*Contained in parts packs

Mounting Hardware Included 

Silicone Sealant Required

REQUIRED TOOLS:

9) Adjustment Knob

2) Photocontrol

12) Support Hook

11) Set Screw

10) Visor

Figure B

Summary of Contents for OLF 2SH 40K 120

Page 1: ... for claims arising out of improper or careless installation or handling of its products INSTALLATION INSTRUCTIONS UOLF_Rev 8 17 15 If further technical assistance is required contact Technical Support at 800 748 5070 LED Security Floodlight Model Number s OLF 2RH 40K 120 OLF 2RH 40K 120 PE PE denotes photocell option Suitable for wall mount or eave mount Not suitable for ground mount installation...

Page 2: ...urn away from lamp lens Do not operate in close proximity to persons combustible materials or substances affected by heat Never connect components under load jacket or damage wire insulation an LED product directly to a dimmer packs occupancy sensor timing directly off a switched circuit will prevent convection or cooling LED products are Polarity Sensitive Ensure proper Polarity before installati...

Page 3: ...it only use wire nut 6 to connect the copper Note If house wiring does not include a ground wire consult your local electrical code for approved grounding methods For proper connection place wire nut over wires and twist clockwise until tight 6 To Connect supply wires use wire nut 6 to connect the black wire to the white neutral supply wire insert mounting screw 3 into center hole of with rubber p...

Page 4: ...not come on or stays on Close Photocontrol cover Light should come on Photocontrol Light should go off light sources enters the photocontol To correct problem eliminate If Photocontrol cover is in closed position it will allow continuous If further technical assistance is required contact Technical Support at 800 748 5070 This LED light provides low maintenance service with no bulbs to change Clea...

Reviews: