background image

Safety Information

1

!

LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com

This manual is intended for qualified installers. Although detailed, it is designed as an overall guide to the installation and not to replace
the manufacturer’s manuals.

All work should be performed in compliance with local and national electrical codes. The installer should assume that voltage is present
at the battery terminals; use insulated tools and gloves. Always turn OFF  equipment connected to the battery, and the Power switch on
the battery. This will isolate the battery from other electrical circuits. This must occur before performing any repairs or maintenance on
the system.

Proper wire size is essential when connecting the inverters, chargers and other equipment in the system. Crimped connections are
required when connecting to the battery terminals.

Read and follow the inverter, charger or other equipment manufacturer’s safety precautions prior to connecting the battery. All
charging equipment must be compatible with Lithium Iron Phosphate battery chemistry.

Links to the installation manuals relevant to this kit are listed at the back of this manual.

Summary of Contents for ionGen GTX12V315A-E2107-CS200RV VICTRON

Page 1: ...GTX12V315A E2107 CS200RV INSTALLATION KIT LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Revision 01 VICTRON 2000 WATT Installer s Guide...

Page 2: ...MAIN DIAGRAM INVERTER DIAGRAM STERLING DIAGRAM SOLAR DIAGRAM PARTS LIST BATTERY INSTALLATION EQUIPMENT MANUALS Table of Contents LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797...

Page 3: ...n OFF equipment connected to the battery and the Power switch on the battery This will isolate the battery from other electrical circuits This must occur before performing any repairs or maintenance o...

Page 4: ...000 watt inverter The kit is limited to 300Amps DC If a larger inverter or battery bank is anticipated in a future expansion then one of our larger kits with higher capacity components is recommended...

Page 5: ...s the following peripheral components three isolation switches positive distribution buss with integrated fuses main battery fuse holder and fuse negative distribution buss Class T fuse holder and fus...

Page 6: ...Main Diagram Inverter Diagram Sterling Diagram Solar Diagram Wiring Diagrams LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 4...

Page 7: ...to isolate the inverter in the case of a malfunction as well as disabling the inverter if work is required on the AC system If the inverter is installed more than five feet from the fuse block the wir...

Page 8: ...ttings monitor data and update software The Victron Smart Solar MPPT charger is connected to the MRBF fuse block via a 40A fuse and an isolation switch The PV solar array is connected to the MPPT char...

Page 9: ...MAIN DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 7...

Page 10: ...er rated at 50A or less and the cable cross section must be sized accordingly Make all connections using proper crimp on connectors do not use twist on connectors The inverter has a Power Assist featu...

Page 11: ...nstallation the inverter chassis must be connected to the vehicle chassis ground via the negative distribution buss The chassis grounding conductor must be not less than one size smaller than the DC p...

Page 12: ...INVERTER DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 10...

Page 13: ...he Sterling BB1230 charger Mercedes recommendation or the BB1260 charger depending on the size of the alternator The charger should be programmed to charge the battery using a Lithium battery profile...

Page 14: ...STERLING DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 12...

Page 15: ...n open circuit voltage that is higher then another circuit breaker with a higher voltage rating must be substituted The charger is connected to the MRBF fuse block via a switch and a 40A fuse The fuse...

Page 16: ...SOLAR DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 14...

Page 17: ...tems 1 BSS 5502100 Class T Fuse Block with Insulating Cover 225 to 400A Blue Sea Systems 1 BSS 5118 Class T Fuse 250 Amp Blue Sea Systems 1 BB123012to12 30A Sterling BB1230 12 to 12 30A Optional BB126...

Page 18: ...Power button for 3 seconds until LED turns off Lithium batteries do not release gas during normal use There are no specific ventilation requirements for battery installation although enough airflow s...

Page 19: ...h resistance path and cause excessive heating of the connection which could then lead to permanent battery damage or fire If you must attach more than one lug to each terminal make sure at least 1 4 o...

Page 20: ...load and not to exceed the battery specifications After installation is complete turn on the battery power by a short press of the Power button The LED indicator should come on to confirm the battery...

Page 21: ...r the manufacturer equipment manuals LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Equipment Manuals Victron Inverter Victron MPPT Solar Charger...