page 8
10. Light Kit Assembly (Optional). (cont.)
diagram 2
diagram 3
diagram 4
diagram 1
reverse switch
11. Testing Your Fan.
light
pull chain
extension
Connect
WHITE
wire from switch housing to
WHITE
wire from light kit fitter. Connect
BLACK
(or
BLUE
) wire from switch housing to
BLACK
wire from light kit fitter. Be sure that
molex connections snap together securely.
Align holes in light kit fitter with holes in
switch housing. Attach light kit fitter to switch
housing with 3 screws that were removed on
previous page. Secure all 3 screws with Phillips
screwdriver.
Attach 4 glass shades using thumbscrews
provided in one of the hardware packs.
Do NOT
overtighten thumbscrews as glass may crack or
break.
Install 4 candelabra base 40 watt max. bulbs
(included).
Important:
When you need to replace bulbs,
please allow bulb(s) and glass shade to cool
down before touching them.
fan
pull chain
extension
white
white
black
black
(or blue)
glass shade
thumb-
screws
bulb
switch housing
light kit
fitter
thumb-
screw
molex
connections
It is recommended that you test fan before finalizing
installation. Restore power from circuit box and wall switch
(if applicable). Test fan speeds with the pull chain on the
switch housing. Start at the OFF position (no blade
movement). First pull will set the fan to HI. Second pull will
set the fan to MEDIUM. Third pull will set the fan to LOW.
Fourth pull will re-set the fan to OFF setting. Test lights
with the pull chain in the middle. (
Refer to
diagram 1
.
) If
fan and/or lights do (does) not function, please refer to
"Troubleshooting" section to solve any issues before
contacting Customer Service.
Turn fan completely off
before
moving the reverse switch.
Set reverse switch to recirculate air depending on the
season:
- DOWN position in summer (
diagram 2
)
- UP position in winter (
diagram 3
)
A ceiling fan will allow you to raise your thermostat setting
in summer and lower your thermostat setting in winter
without feeling a difference in your comfort.
Important
: Reverse switch must be set either
completely
UP
or
completely DOWN
for fan to function. If the reverse
switch is set in the
middle
position (
diagram 4
), fan will not
operate.
Attach pull chain extensions supplied or custom pull chain
extensions (sold separately) may be attached to the ends
of the pull chain.