background image

 

 

 

 

 

ECP-105T [EUM-C] 

 

User Manual 

ECP-105T 

Touch Panel 

 

 

 

 

 

 
 

 

 

 

 

Summary of Contents for ECP-105T

Page 1: ...ECP 105T EUM C User Manual ECP 105T Touch Panel...

Page 2: ...IAGRAM 3 2 OPERATION 4 2 1 ZONE SETTING 4 2 1 1 EDX SYSTEM 4 2 1 2 PURPOSE OF ZONE SETTING 4 2 1 3 ZONE SETTING MODE OF DIP 5 2 1 4 CANCEL ZONE SETTING MODE 5 2 2 SCENE RECALL 5 2 3 KEY LOCK UNLOCK FU...

Page 3: ...e 2 Can recall 4 scenes 3 256 level dimming solutions enable more complicated lighting change 4 Lock unlock setting 5 IR remote control 6 Two dry contacts input 1 2 Specification 1 Protocol EDX 2 Sign...

Page 4: ...ECP 105T EUM C 2 Rear Side 1 Scene 1 4 2 OFF button 3 Panel light window 4 IR window 5 DIP switch...

Page 5: ...ECP 105T EUM C 3 1 4 Open the Upper Cover with screwdriver 1 5 System Diagram...

Page 6: ...er For instance ECP panel Zone 1 can control EDX Zone 1 One ECP panel can control one EDX shown as below 2 1 2 Purpose of Zone Setting One ECP 105T can control 1 8 zones at the same time in EDX before...

Page 7: ...DIP 8 means 1st 8th zone 2 1 4 Cancel Zone Setting Mode The user can cancel the zone setting value if each of DIP is OFF 2 2 Scene Recall Press 1 4 to recall the scene For instance press 1 to recall S...

Page 8: ...Control ECP 105T can receive IR 0501 to recall scene IR remote control functions setting turn on turn off DIP10 ON turn on IR remote control function DIP10 OFF turn off IR remote control function 2 5...

Page 9: ...isconnecting input 2 for 30s In NEX 1 Set ECP 105T single zone the zone is 01 STEP1 Send command of SERVICE18 by actuating input 1 DP E700 executes the command of SERVICE18 80 01 55 01 00 12 00 00 05...

Page 10: ...command of SERVICE26 80 03 55 01 00 1A 00 00 05 STEP2 Send command of SERVICE27 by disconnecting input 1 DP E700 executes the command of SERVICE27 80 03 55 01 00 1B 00 00 05 STEP3 Send command of SERV...

Page 11: ...zone STEP1 Send command of recalling SC5 by actuating input 1 DP E700 executes SC5 of Zone 8 STEP2 Send command of recalling SC OFF by disconnecting input 1 DP E700 executes SCOFF of Zone 8 STEP3 Send...

Page 12: ...0 20 00101000 21 10101000 22 01101000 23 11010000 24 00011000 25 10011000 26 01011000 27 11011000 28 00111000 29 10111000 30 01111000 31 11111000 32 00000100 33 10000100 34 01000100 35 11000100 36 001...

Page 13: ...volcanic eruption tsunami or other factors beyond Lite Puter control c The cost of installing reinstalling adjusting repairing or reprogramming the product d Other products or devices which are offer...