Lister Petter LT and LV Operators Handbook
page 8
2.3 Cold Starting Aid
An optional cold starting aid may be
fitted to the combustion air intake port
for use when the ambient temperature
is below -10°C (14°F).
CAUTION
The device must not be used more than
three times in succession during the same
attempt to start the engine.
1. With the fuel turned on turn the engine
for up to 20 revolutions to prime the
fuel and lubrication systems.
2. Withdraw the plunger (A) and fill one
third of the cup (B) with the same type
of lubricating oil as used in the engine.
Figure 2.3.1 Cold Start
3. Replace the plunger and inject the oil
just before starting the engine.
2.4 Hand Starting
Before attempting to start the engine
refer to "2.2 Starting Handle Precautions".
1. Select the excess fuel position by
gently pulling the engine control lever
(A) outward over the middle catch (B)
and turning it fully clockwise.
Figure 2.4.1 Engine Control
2. If a variable speed control lever is fitted
move it to the fast position.
3. Move the decompressor lever towards
the flywheel.
Figure 2.4.2 Decompressor Lever
4. If the ambient temperature is below -
10°C (14°F) refer to "2.3 The Cold
Starting Aid".
5a. If using a non-limited kick-back
handle:
Insert the correct handle, refer to 'A' in
'Figure 2.2.1 Starting Handles', into the
starting housing.
Slowly rotate the handle in the direction
of cranking until it fully engages.
5b. If using a limited kick-back handle:
Swivel the starting handle housing
cover (C) to one side, lift the spring
loaded plunger (D), if fitted, and insert
the correct handle, refer to 'B' in 'Figure
2.2.1 Starting Handles', into the
housing.
Slowly rotate the handle in the direction
of cranking until it fully engages.
2. Operating Instructions
- cold start aid and hand starting