18
iFerm Nano Tank
Installation
4.2
Attaching the connecting cable
The connecting cable carries all signals that
iFerm Nano Tank
requires for the power supply, data bus and control of the
valves. It must be properly laid and connected.
DANGER! – Electric shock
Always disconnect the system from the power supply
before working on the electrical connection.
iFerm Nano Tank
switches itself on automatically when
connected to a power supply, see
. Therefore, do not switch on the power
supply until connection and installation have been
completed.
¨
First plan the laying route for the connecting cable before
you make the electrical connection.
¨
Ensure that there is no trip hazard,
and also that there is sufficient
strain relief and kink protection.
¨
Keep liquid running along the cable
away from the controller housing by
forming a drip loop under the cable
screw connection.
Attention!
To protect against damage, you should lay the
connecting cable along the level indicator or in a
separate conduit.