ON
1
2
3
4
5
6
Zone Selection*
DIP 1
DIP 2
ZONE Setting
OFF
OFF
ZONE1
OFF
ON
ZONE2
ON
OFF
ZONE3
ON
ON
ZONE4
Heat Pump
(selected models)
DIP 3
Reserved
Furnace
DIP 4
OFF
Furnace Off
ON
Furnace On
Electric Heat
(selected models)
DIP 5
OFF
Electric Heat
Off
ON
Electric Heat
On
Analog / Digital
DIP 6
OFF
Digital
ON
Analog
Wire Connection - Digital Furrion Wall
Controller/Thermostat
DANGER
Electrical Shock Hazard
●
Disconnect power before servicing.
●
Provide grounding in compliance with all applicable
electrical codes.
Failure to obey this warning could result in death or serious
injury.
1. Familiarize yourself with the ceiling controller and wire
harnesses.
NOTE:
When connecting to a Furrion wall controller/
thermostat, the analog harness bundle is not used and can
be tucked away. The ends do not need to be capped or
taped.
Wall Thermostat Cable
(4-wire harness)
Analog Cable (8-wire
harness)
Furnace Cable (2-wires)
12V DC Power Cable (2-wires)
Freeze Sensor Cable (wire with
copper tip and blue plastic clip)
LED Cable (1 white
cable)
2. Loosen the strain relief and compartment cover of the
control box and pass the 115VAC power cord through
the strain relief hole and re-tighten the cable clamp until
properly restrained. Do not over tighten.
3. Make wire connections following the below color codes.
Black - Hot
White - Neutral
Green/yellow - Ground
Strain Relief
4. Fit all cables into the cable compartment and tuck any
excess wires up out of the way. Tighten the cover with
screw.
5. Locate the four thermostat cables of the control box (red,
green, blue and purple), which are tied together and tagged
with “
To wall thermostat
”, and connect them to the
thermostat wire that extends to the wall.
IMPORTANT:
Note the function marked on the wire end
and carefully trace and mark its function at the end of the
wire extension so that proper connection can be made at
the wall controller / thermostat.
Crossing the wires could prevent the control from
operating properly, or even cause damage. If uncertain,
perform a continuity test through each extension to
confirm.
Thermostat Cable
6. If applicable, locate the furnace wires from the ceiling
controller, which are two separate brown wires tagged
with “
FURN
”. Connect them with the 12V+ wire from the
furnace, and the return wire to the furnace.
NOTE:
Polarity does not matter, connection can be freely
made to either wire. Do not connect the two brown “
FURN
”
wires together.
English
CCD-0005730 Rev: 04-25-22
- 9 -