M²-Sync Room Slideout System 

DESCRIPTION

Stops Not Programmed

Slideout motor drawing 
excessive current

Slideout Motor Short

Slideout Motor Open

No signal on sensor wire

Excessive Battery Voltage 
(above 18V when room 
movement requested)

Rail did not resync with 
opposing rail 

Room lock motor drawing 
excessive current

Room Lock Motor Short

Room Lock Motor Open

Room Lock Timeout

PROBABLE CAUSE

No stop locations have been set for the 
control

Excessive system/room drag, obstruc-
tion, improper stop locations or 
damaged component

Shorted wiring or motor

Bad connection, motor or blown fuse

Bad wire connection or sensor

Bad Battery

Excessive system/room drag, obstruc-
tion, improper stop locations or 
damaged component

Excessive drag or obstruction or 
damaged component

Shorted wiring or motor

Bad connection or motor

Bad wire connection, obstruction, 
broken component or low voltage

TYPE

Major

Minor

Minor

Minor

Major

Minor

Major

Minor

Minor

Minor

Minor

CODE

1

2

3

4

5

6

7

8

9

10

11

POSSIBLE SOLUTIONS

Stops need to be reprogrammed by an
authorizied dealer

Remove obstruction, re-adjsut room, reset 
stops, or replaced damaged component

Inspect motor harness wires and motor for 
shorts. Replace shorted component

Repair bad wire connection, replace motor or 
fuse

Repair bad wire connection or replace motor

Replace battery

Remove obstruction, re-adjsut room, reset 
stops, or replaced damaged component

Remove obstruction  or replace damaged 
component

Inspect motor harness wires and motor for 
shorts. Replace shorted component

Repair bad connection, or replace motor 

Remove obstruction, replace battery, repair 
bad wire connection or fix broken compo-
nents in room lock

Use this troubleshooting chart if your touchpad looks like the picture above

.

(Usually used with Control Box 1510000143 and 1510000198)

CCD-0002533

Summary of Contents for Power Gear M2-Sync

Page 1: ...ng Your Power Gear slide out system has been designed to require very little maintenance To ensure the long life of your slide out system read and follow these few simple procedures excess build up of...

Page 2: ...om locks The RED LEDs indicates a fault or problem with the system Figure 1 Refer to the Fault Diagnostics in this manual for additional information Prior to moving the slideout room make sure the eng...

Page 3: ...ng chart depending on which Touch Pad you have For example if you have Touch Pad Version A and you are seeing 5 red flashes 2 green flashes it means your slideout is drawing excessive current on motor...

Page 4: ...7 Major Slideout Motor Open Bad connection motor or Repair bad wire connection replace motor blown fuse or fuse 8 Major No signal on motor sensor Bad wire connection or sensor Repair bad wire connecti...

Page 5: ...motor Bad connection or motor Bad wire connection obstruction broken component or low voltage TYPE Major Minor Minor Minor Major Minor Major Minor Minor Minor Minor CODE 1 2 3 4 5 6 7 8 9 10 11 POSSI...

Page 6: ...uthorized dealer after the system has been overridden A Emergency Retract Mode use this procedure when there is NO loss of power or electrical problem with the system 1 Remove the touchpad Fig 1 from...

Page 7: ...following procedure must be followed Start at the front of the coach release the motor brake rotate that shaft approximately 1 8 turn re apply the motor brake Proceed to the next rail with motor Relea...

Page 8: ...and Service Manual for Slideout Control Box 1510000122 3010002088 Installation and Service Manual for Slideout Control Boxes 1510000143 and 1510000198 82 SO521 Encoder Test 1 Dual Sync Slide Controlle...

Reviews: