Troubleshooting - Touch Pad B
Page 5
M²-Sync Room Slideout System
DESCRIPTION
Stops Not Programmed
Slideout motor drawing
excessive current
Slideout Motor Short
Slideout Motor Open
No signal on sensor wire
Excessive Battery Voltage
(above 18V when room
movement requested)
Rail did not resync with
opposing rail
Room lock motor drawing
excessive current
Room Lock Motor Short
Room Lock Motor Open
Room Lock Timeout
PROBABLE CAUSE
No stop locations have been set for the
control
Excessive system/room drag, obstruc-
tion, improper stop locations or
damaged component
Shorted wiring or motor
Bad connection, motor or blown fuse
Bad wire connection or sensor
Bad Battery
Excessive system/room drag, obstruc-
tion, improper stop locations or
damaged component
Excessive drag or obstruction or
damaged component
Shorted wiring or motor
Bad connection or motor
Bad wire connection, obstruction,
broken component or low voltage
TYPE
Major
Minor
Minor
Minor
Major
Minor
Major
Minor
Minor
Minor
Minor
CODE
1
2
3
4
5
6
7
8
9
10
11
POSSIBLE SOLUTIONS
Stops need to be reprogrammed by an
authorizied dealer
Remove obstruction, re-adjsut room, reset
stops, or replaced damaged component
Inspect motor harness wires and motor for
shorts. Replace shorted component
Repair bad wire connection, replace motor or
fuse
Repair bad wire connection or replace motor
Replace battery
Remove obstruction, re-adjsut room, reset
stops, or replaced damaged component
Remove obstruction or replace damaged
component
Inspect motor harness wires and motor for
shorts. Replace shorted component
Repair bad connection, or replace motor
Remove obstruction, replace battery, repair
bad wire connection or fix broken compo-
nents in room lock
Use this troubleshooting chart if your touchpad looks like the picture above
.
(Usually used with Control Box 1510000143 and 1510000198)
CCD-0002533