Troubleshooting - Touch Pad A

Fault 

Fault 

Description 

         Probable Cause 

            Possible Solutions

Code Type 

Major 

Stop Not Programmed 

         No stop locations has 

            Stops need to be reprogrammed by an

         been set for the control 

            authorizied dealer

Minor 

Battery Dropout Voltage. 

         Bad Battery, bad wire conne- 

            Repair bad wire connection, short or replace

Voltage dropped below 8.0V          ction or short in system   

            battery

Minor 

Low Battery Voltage.  Voltage          Bad wire connection from  

            Repair bad wire connection or replace battery

is below 10.5V when room           battery to control or low 
movement was initiated 

         battery

Minor 

Excessive Battery Voltage. 

         Bad battery 

            Replace battery

Battery 

Voltage 

is 

above

18.0V when room movement
was 

initiated.

Minor 

Slideout motor drawing 

         Excessive system/room drag, 

            Remove obstruction,  re-adjust room, reset

excessive current   

         obstruction, improper stop 

            stops, or replace damaged

         locations or damaged    

            component

         component 

 

Major 

Slideout Motor Short 

         Shorted wiring or motor  

            Inspect motor harness wires and motor for
            shorts.  Replace shorted component.

Major 

Slideout Motor Open 

         Bad connection, motor or 

            Repair bad wire connection, replace motor

         blown fuse. 

 

            or  fuse

Major 

No signal on motor sensor           Bad wire connection or sensor 

            Repair bad wire connection or replace motor

Out 

(yellow) 

wire

Major 

No signal on motor sensor           Bad wire connection or sensor 

            Repair bad wire connection or replace motor

Out 2 (blue) wire   

10 

Major 

No signal on motor sensor           Bad wire connection or sensor 

            Repair bad sensor or motor lead connections. 

wires yellow or blue 

            Lastly, replace motor.

11 

Minor 

Room lock motor drawing 

         Excessive drag or obstruction 

            Remove obstruction or replace damaged

excessive current   

         or damaged component 

            component

12 

Major 

Room lock motor short 

         Shorted wiring or motor  

            Inspect motor harness wires and motor for 
            shorts.  Replace shorted component

13 

Major 

Room lock motor open 

         Bad connection or motor 

            Repair bad connection or replace motor

14 

Minor 

Room lock timeout  

         Bad wire connection,  

 

            Remove obstruction, replace battery, repair

         obstruction, broken component              bad wire connection of fix broken component
         or low voltage  

             in room lock 

Page 4

M²-Sync Room Slideout System 

Use this troubleshooting chart if your touchpad looks like the picture above

.

(Usually used with Control Box 1510000122)

CCD-0002533

Summary of Contents for Power Gear M2-Sync

Page 1: ...ng Your Power Gear slide out system has been designed to require very little maintenance To ensure the long life of your slide out system read and follow these few simple procedures excess build up of...

Page 2: ...om locks The RED LEDs indicates a fault or problem with the system Figure 1 Refer to the Fault Diagnostics in this manual for additional information Prior to moving the slideout room make sure the eng...

Page 3: ...ng chart depending on which Touch Pad you have For example if you have Touch Pad Version A and you are seeing 5 red flashes 2 green flashes it means your slideout is drawing excessive current on motor...

Page 4: ...7 Major Slideout Motor Open Bad connection motor or Repair bad wire connection replace motor blown fuse or fuse 8 Major No signal on motor sensor Bad wire connection or sensor Repair bad wire connecti...

Page 5: ...motor Bad connection or motor Bad wire connection obstruction broken component or low voltage TYPE Major Minor Minor Minor Major Minor Major Minor Minor Minor Minor CODE 1 2 3 4 5 6 7 8 9 10 11 POSSI...

Page 6: ...uthorized dealer after the system has been overridden A Emergency Retract Mode use this procedure when there is NO loss of power or electrical problem with the system 1 Remove the touchpad Fig 1 from...