Troubleshooting - Touch Pad A
Fault
Fault
Description
Probable Cause
Possible Solutions
Code Type
1
Major
Stop Not Programmed
No stop locations has
Stops need to be reprogrammed by an
been set for the control
authorizied dealer
2
Minor
Battery Dropout Voltage.
Bad Battery, bad wire conne-
Repair bad wire connection, short or replace
Voltage dropped below 8.0V ction or short in system
battery
3
Minor
Low Battery Voltage. Voltage Bad wire connection from
Repair bad wire connection or replace battery
is below 10.5V when room battery to control or low
movement was initiated
battery
4
Minor
Excessive Battery Voltage.
Bad battery
Replace battery
Battery
Voltage
is
above
18.0V when room movement
was
initiated.
5
Minor
Slideout motor drawing
Excessive system/room drag,
Remove obstruction, re-adjust room, reset
excessive current
obstruction, improper stop
stops, or replace damaged
locations or damaged
component
component
6
Major
Slideout Motor Short
Shorted wiring or motor
Inspect motor harness wires and motor for
shorts. Replace shorted component.
7
Major
Slideout Motor Open
Bad connection, motor or
Repair bad wire connection, replace motor
blown fuse.
or fuse
8
Major
No signal on motor sensor Bad wire connection or sensor
Repair bad wire connection or replace motor
Out
1
(yellow)
wire
9
Major
No signal on motor sensor Bad wire connection or sensor
Repair bad wire connection or replace motor
Out 2 (blue) wire
10
Major
No signal on motor sensor Bad wire connection or sensor
Repair bad sensor or motor lead connections.
wires yellow or blue
Lastly, replace motor.
11
Minor
Room lock motor drawing
Excessive drag or obstruction
Remove obstruction or replace damaged
excessive current
or damaged component
component
12
Major
Room lock motor short
Shorted wiring or motor
Inspect motor harness wires and motor for
shorts. Replace shorted component
13
Major
Room lock motor open
Bad connection or motor
Repair bad connection or replace motor
14
Minor
Room lock timeout
Bad wire connection,
Remove obstruction, replace battery, repair
obstruction, broken component bad wire connection of fix broken component
or low voltage
in room lock
Page 4
M²-Sync Room Slideout System
Use this troubleshooting chart if your touchpad looks like the picture above
.
(Usually used with Control Box 1510000122)
CCD-0002533