Operator manual Konstanz STG/ASA 5/20 Version 8.0 (01/2010)
Technical data:
Allowable load carrying capacity: max. 300 Kg
Continuous audio pressure level:
< 70 dB (A)
Vibrations:
< 0.5 m/s² (Measurement uncertainty
%
3
)
Speed:
ca. 0.1 m/s
Platform voltage:
24VDC
Loading device voltage:
230VAC (55W)
Conditions of the surroundings:
Temperature range: -20°C to +60°C
Rel. humidity: max. 100%
Test obligations
Whether the platform lift Konstanz is subject to an obligatory test depends on the respective
national regulations and lies in the responsibility of the operator. These must absolutely be
checked and maintained. In Germany a test obligation applies for systems with a conveyance
height
m
3
.
In any case, evidence must be provided and documented before the initial usage in accordance
with EN81-40.
The platform lift is subject to at least annual maintenance in accordance with the maintenance
manual. We recommend concluding a maintenance agreement with your specialized company.
Intended purpose
The platform lift is intended for the transport of wheel chair occupants or persons with
restricted mobility.
The platform travels between specified access points on a firmly installed rail, which is
designed straightly. The platform is guided by the rail over a stairway or an accessible,
inclined surface.
Only instructed persons may operate the system..
Following conveyer profiles are planned:
1. Transport of a person sitting in a wheel chair
2. Transport of a person sitting on a folding chair
3. Transport of a person standing on the platform insofar as sufficient head clearance
exists, the person has sufficient standing stability and can securely hold onto the hand
rails (separate document set required, upon request).
4. Transport of an additional person, insofar as there is sufficient space on the platform
and the allowable load carrying capacity is not exceeded.
2.
1.1
1.2
1.3
2.1