Operator manual Konstanz STG/ASA 11/20 Version 8.0 (01/2010)
4.1
4.2
4.3
4.4
The main switch
The main switch (red key) is located within the platform, behind the covering
(
S.7.8/item 6
). Counterclockwise rotation allows the key to be removed and thus the
power supply interrupted. (Opening of the covering see 4.7.2 or 4.7.3). The main
switch should be operated by technical personnel.
Total discharge protection and charging
The platform lift Konstanz is equipped with automatic charging devices. The
charging occurs automatically when the platform lift drives to a charging station. The
batteries require no maintenance.
All platform lifts Konstanz are equipped with an acoustical total discharge
protection. This acoutistical signal device should protect the batteries against total
discharge.
If the battery voltage falls below 22 V, a beeping sound occurs in approx. 5-sec.
intervals. In this case you should drive immediately to the nearest, if possible the
lower charging station and charge the lift for several hours (this occurs automatically
at the charging site). The beeping sound ceases after proper charging. The sound can
be stopped by pressing the emergency-off switch. This has no influence on the
loading process.
Control of the loading
The platform lift Konstanz is equipped with an overloading protection (acoustically
and optically). For the metal cover, the orange lamp is extinguished on the cover.
(
S.7/item. L2
) and for the plastic cover, the background lighting is
extinguished.(
S.8/Pos.1
). In the case of overloading an additional continuous tone is
transmitted by the internal beeper. As a basis, the entire loading process takes place
in the middle of the platform floor. If the overloading protection reacts, reduce the
weight. Possibly positioning closer to the direction of the track is sufficient.
The loading device
(control lamps)
The control lamps on the loading device show the respective status of the loading
device. Thereby, two different designs of the loading device must be distinguished.
A main feature is the number of light diodes
3 Light diodes
Green
Yellow
Red
No power on the loading device Off
Off
Off
No battery connected
On
Flashing (short)
Off
Loading
On
Blinks slowly
Off
Battery fully charged
On
On, extinguishes briefly
every 2 seconds
Off
1 light diode
LED
No power on the loading device Off
No battery connected
Red
Loading
Yellow
Battery fully charged
Green
Note: If the Lift, outside of the stopping point, is not charged 30 seconds after the last
motor motion, an acoustical signal sounds.