Instructions
Stump cutter SFB 50
12 - 20
150130-04-EN BA SFB 50 / 22.03.2019
•
Attention:
The leak oil line must be conducted to the hydraulic oil tank free
of pressure. Under no circumstances must the leak oil line of the
hydraulic motor be subjected to pressure.
Incorrect pressurization will destroy the seals in the hydraulic
motor and cause oil to leak out.
•
Please observe the labeling of the connections
– Pressure line
(P) and return line (T).
•
The return line must be sufficiently wide, i.e. its nominal width
must be larger than the pressure line!
•
Attention:
When the hydraulic system is closed, the hydraulic oil tank
is under pressure.
Connection for
excavator pressure
line
Return line for leak
oil
–
pressure-free
Return line to tank -
pressure-free
Abb. 3