The quantity of clamps depends on the pressure intensity of local wind and snow. If the
pressure is beyond the expected value, additional clamps or brackets shall be employed to guarantee
that the module can bear that pressure. The torsion force applied for installation shall be big enough
so that the module can be properly fixed (torsion force: 17-23N
m), as shown in the figure below :
Fig
A
Fig
B
The maximum load of the module in the table below is for beamless installation of the module
,
(maximum load
:
downward
≤
5400pa
,
upward
≤
2400pa , Installed with Beams)
The clamps and installation methods in the table 2 are recommended to match the 60 cells
transparent glass bifacial modules manufactured by Linyang Photovoltaic( In table 1) .
Tab 1 Types of modules
:
5BB modules
5BB half cut modules
MBB modules
BP60T
QP60T
MP60T
BP60TL
QP60TP
MP60TL
BP60TP
MP60HT
BP60TPL
MP60HTL
A
A
Four clamps must be installed on long
side
;
(
Installed without Beams
);
The beam should be perpendicular to the
long side
;
(
Installed with Beams
)
A
B
Six clamps must be installed on long side
;
(
Installed without Beams
);