RS232 Knekt Interface
13
[BAUD=p]
Sets the RS232 baud rate to the specified value. The default baud rate after power up is 9600. The
RS232 port remains configured to operate with 7 data bits, 1 stop bit and even parity.
Command
Response
Description
[BAUD=rate]
!r<CR>
Sets the baud rate and returns
the response at the new rate.
rate = 110, 150, 300, 600, 1200,
2400, 4800, 9600, 19200 or
38400
[PC=p]
Sets or reads the PC port address of the room interface card. The maximum number of room
interface cards allowed is 16, providing 128 rooms.
Command
Response
Description
[PC=numOFmax]
!<CR>
Sets the PC port address
[PC=?]
! PC=numOFmax <CR>
Reads the PC port address
[rAMP=name]
Selects the “amplifier” device command set, or returns the name of the currently selected
“amplifier” device.
Command
Response
Description
[rAMP=LNRCV]
!r<CR>
Selects Knekt line receiver commands
[rAMP=MAJIK]
!r<CR>
Selects Majik/Wakonda commands
[rAMP=KAIRN]
!r<CR>
Selects Kairn commands
[rAMP=AVPREvalue]
!r<CR>
Selects AV5103 preamp commands and
address (value = 0 to 9)
[rAMP=RC5]
!r<CR>
Selects generic RC5 commands
[rAMP=?]
!rAMP=name<CR>
Returns the selected command set name