Installation Guide E1100
NTI AG, LinMot
Installation Guide E1100 26.01.2006
Page 5/20
Functionality
E1100-MP
E1100-MP-
HC
E1100-MT
E1100-MT
-HC
E1100-RS
E1100-RS
-HC
E1100-C
O
E1100-C
O
-HC
E1100-D
N
E1100-D
N
-HC
E1130-DP
E1130-DP
-HC
E1100-
GP
E1100-
GP-H
C
Supply Voltage
Motor Supply 72VDC (24...80VDC)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Logic Supply 24VDC (22...26VDC)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Motor Phase Current
4A
peak
●
●
●
●
●
●
●
15A
peak
●
●
●
●
●
●
●
Controllable Motors
LinMot
P01-23x…
●
●
●
●
●
●
●
●
●
●
●
●
●
●
P01-37x…
●
●
●
●
●
●
●
●
●
●
●
●
●
●
P01-48x…
●
●
●
●
●
●
●
●
●
●
●
●
●
●
DC
Motors
●
●
●
●
●
●
●
●
●
●
Brushless DC / EC Motors
●
●
●
●
●
●
●
●
●
●
Command Interface
MPC with 8 Commands
●
●
●
●
●
●
MPC with 256 Commands
●
●
●
●
RS232
up to 115.2 kBaud
●
●
●
●
●
●
RS485
up to 115.2 kBaud
●
●
●
●
●
●
CANOpen
up to 1MBaud
●
●
●
●
●
●
DeviceNet
125, 250, 500 kBaud
●
●
●
●
●
●
PROFIBUS DP
up to 12 MBaud
●
●
External Position Sensor
Incremental
RS422 up to 2 MHz
●
●
●
●
●
●
●
●
●
●
●
●
SinCos
1Vpp up to 10 kHz
●
●
●
●
●
●
●
●
●
●
●
●
Synchronisation
Master Encoder In/Out RS422 up to 2 MHz
●
●
●
●
●
●
●
●
●
●
Configuration
RS232
Configuration
●
●
●
●
●
●
●
●
●
●
●
●
●
●
CAN Multi Axes Configuration
●
●
●
●
●
●
●
●
●
●
●
●