5.9.4 Adjusting the display
The way the recording data are displayed on the screen can be adjusted from the display
panel. The adjustable parameters are:
•
curve color
•
curve offset (relative to the center of the graph display)
•
magnification of the curve
The curves can be moved and zoomed in or out using the mouse or the buttons in the
display panel.
After the recorded the data have been loaded from the electronic unit up to the PC, the
data are displayed in the display window. If the data does not fit in properly, the ‘Fit
view’ function may be used for an automatic adjustment. The all data will be displayed.
5.9.5 Starting and stopping the Oscilloscope
After clicking on the “Start” button, all the values are checked and sent to the
LinMot
®
electronic unit. At this point the software on the
LinMot
®
electronic unit waits until the
trigger condition is satisfied and then starts the recording. As soon as the values have
been recorded the
LinMot
®
electronic unit notifies the PC that the data are ready and
available. The PC then reads the data from the electronic unit and displays it. There are
however three exceptions to this behavior.
When the “Multishot” function is selected, the Start button must be clicked first, in order
to start the Oscilloscope on the
LinMot
®
electronic unit. When the desired event occurs
the last event recorded can be transmitted to the PC by clicking on the “Shot” button. If
the “Shot” button is clicked before the recording is finished, the recording is finished
first.
If the recording mode is set to “Pretrigger” and the trigger mode is “Manual”, the
Oscilloscope is started on the
LinMot
®
electronic unit by clicking on the “Start” button.
The trigger is then released by clicking on the “Shot” button. As soon as the recording is
finished, the data are transmitted to the PC and displayed.
After the recording has been started by clicking on the “Start” button, the button text
changes to “Abort”. The “Abort” button can be used to abort the current recording.
5.9.6 Printing recorded curves
The actual graph can be printed to any printer by clicking on the “Print” button.
Fit View
Start
Multishot
Pretrigger
Abort