background image

 
 
 

 
 
Linkcom France 

11 rue du Soleil Levant 92140 CLAMART                                                                                     Copyright © 2009 – Linkcom – All rights reserved 

 
 

 
 
 
 

Link Smile DoorPhone 

 

 

 

 
 
 
 

Manual 

v1.0 

Please find the latest version of the manual and firmware at www.linkcom.fr 

 
 
 

 
 
 

Summary of Contents for link smile

Page 1: ...kcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2009 Linkcom All rights reserved 1 Link Smile DoorPhone Manual v1 0 Please find the latest version of the manual and firmware at www linkcom...

Page 2: ...ing call 8 3 3 2 Incoming call 8 4 Parameter programming 8 4 1 Programming from a telephone by DTMF 8 4 1 1 Parameter programming 9 4 2 PC programming Smile DoorPhone Config programm 9 5 Parameter des...

Page 3: ...s forgotten the incoming call is going directly to programming mode and you can set new password 2 Heating switch ON integrated heating of motherboard to increase resistance against condensation water...

Page 4: ...Linkcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2011 Linkcom All rights reserved 4 2 Installation 2 1 Assembly Open and close the cover Dismounting lighting of nameplate...

Page 5: ...ART Copyright 2011 Linkcom All rights reserved 5 2 2 Wall mounting The installation is made by a screwing and dowels Return lighting nameplate after mounting on the wall Each button has its separate n...

Page 6: ...e used also for electrical lock powering Then we recommend power supply 12V 1A You can also use 24V DC power supply It is useful mainly at installations where power supply is already installed and it...

Page 7: ...2 Visitor at the door When the visitor finds the desired name and push it the Smile DoorPhone pick up the line and play the tone line pick up when is not switch off by parameter 62 and calls the phone...

Page 8: ...r dialing the PBX extension number to which the unit is connected the unit will ring for the set number of rings parameter 51 the unit will lift up and it is possible to speak The possibilities are th...

Page 9: ...ay also be selected to end programming mode To program a parameter enter the parameter number followed by the value you wish to set The unit will either respond with the Parameter Confirmation Tone or...

Page 10: ...e stored Refer to the table for other choices Numbers saved in parameter 2 are numbers of second group or numbers of Night mode Default settings doesn t erase as same as changed those saved numbers No...

Page 11: ...utton for call prolongation or 10 sec before Maximum Call Duration the unit will emit a tone Pressing this button will prolong the call Parameter Value Description Default 43 g bb End call 00 99 0 9 1...

Page 12: ...it e 0 for 2 Group mode e 1 for Day Night mode Parameter Value Description Default 4 k End call by push again the same button 0 1 1 k line hanging up by push of same button k 0 feature is switch off k...

Page 13: ...ss dialing up to 2 seconds after line on hook Parameter Value Description Default 56 hh Number of rings before hanging up or group mode switching 04 99 12 h specifies the amount of time spent ringing...

Page 14: ...rrespond to 500 1400ms Time p is also time of pause between numbers at pulse dialing Parameter Value Description Default 507 uu Level of sending tone DTMF dial in dBm 04 16 10 uu level of sending tone...

Page 15: ...ing to call 0 1 0 With this feature you can identify at PBX calling from the doorphone just up knocking into call u 0 knocking to call is off u 1 knocking to call is on Parameter Value description Def...

Page 16: ...eres setting Parameter Value Description Default 71 gg Reception loudness 01 16 TRH 07 72 ff Transmission loudness 01 16 MIC 07 73 rr Speaker loudness 01 16 SPK 07 gg ff rr 2 digits in range 01 16 Aft...

Page 17: ...Fast switching voice automatic 1 4 4 is slowest 2 At Parameters 75 76 is described principal of acoustic shock suppression Speed of circuit switching between incoming and outgoing sound is setup by Pa...

Page 18: ...mbers stored in memory Parameter Value Description Default 81 Deletes all numbers in group 1 Day mode 82 Deletes all numbers in group 2 Night mode 83 Default settings only for parameters 3x 84 Default...

Page 19: ...intercom by phone 00 99 0 9 155 266 44 xxxx Service password 0000 9999 0000 45 dd Command to switch into DAY 00 99 0 9 11 46 nn Command switch into NIGHT 0099 0 9 10 47 e Door intercom dial mode 0 1...

Page 20: ...number 0 1 0 6 t Delay start for PBX s with extension test Siemens 0 1 0 71 gg Reception loudness 01 16 16 is highest TRH 07 72 ff Transmission loudness 01 16 16 is highest MIC 07 73 rr Speaker loudn...

Page 21: ...l 115nF Line OFF HOOK Bandwidth 300Hz 3400 Hz 20 60mA Ringing impedance 2Kohm 25 60 Hz Sensitivity of ringing detector min 10 25 V Pulse dial 40 60 ms Tone dial level 6 and 8 dB 20 60 mA Sensitivity o...