All rights are reserved to Linkcom
classe
DR
classement
LinkDoor
Number
001
date
15/04/05
page
17/31
o – o = 0 dialing as on normal phone (all number of called person should be dialled on keypad).
o =1 Only 2-digit from memory tablevare dialed on keypad
ATTENTION !!
This parameter setting will sharply influence keypad function.
List of related parameters:
1 2 47 48 53 8# 84
2.6 Time
Parameters
Parameter Value
Meaning
Main
Exam.1 Exam.2
51 q
Number of ring until door
phone pickup
2 1 2
q – Laps of time signaled by tone before the Door Phone pick up the line
Doorphone lifts up among rings namely 2 sec. after detection q – times rings (The number can be set from 1 to 9)
List of related parameters:
44 8# 85
Parameter Value
Meaning
Main
Exam.1 Exam.2
52
d
Maximum call duration
2
2
1
d – Time setting for communication between Door Phone and PBX
Time can be extended during conversation by dialing from phone (* or #) before or when hearing hanging up signal
List of related parameters:
42 8# 85
Parameter Value
Meaning
Main
Exam.1 Exam.2
53 w
Time between press
buttons for password
2 2 2
w – max. time [sec] among button presses [range 1-9]
Direct Call Buttons (U4N,M4N)
-
Relay activation – if time between two pressed Direct Call Buttons (C4N or M4N) is bigger than w time, the
password is not evaluated correctly.
-
Password Dialing – if the button pressed, is the first password number for Relay activation, first digit will be
associated to w time.
Keypad UCKN
-
Relay activation – if time between two pressed digits is bigger than w time, the code is not evaluated
correctly.
-
Dialing as on a phone, if time after pressed button is bigger than w time, then the dialing starts. If the number
is incomplete, it is necessary to hang up by pressing (X button) and then dial again.
-
Dialing from memory table, if time following the first pressed button is longer than w time, then the entry of
memory number has to be repeated.
List of related parameters:
1 2 32 33 34 47 48 49 8# 85
Parameter Value
Meaning
Main
Exam.1 Exam.2
54 z
Hangup Time before
redial[s]
2 2 2
z – time in [sec] for which the Doorphone will hang up, before repeated dialing (ex: re-activating direct call button
during a call or dialing or after busy tone detection) [range 1-5]
List of related parameters:
8# 85
Parameter Value
Meaning
Main
Exam.1 Exam.2
55 z
Time for initiation dialing
[s]
1 1 1
z – time in [sec] after Doorphone lifting up before dialing [range 1-5]. This time is different for each exchange, but
most exchanges usually manage to process dialing up to 2 seconds after line lifting up.
List of related parameters:
8# 85