Choosing a Configuration
11
© 2009 Link
Configuration: 6 Cylinder, direct spark, sequential injection, turbocharged
Injection 1
Wire Inj 1 to cyl
1, 2 to 2, 3to 3
etc...
Use spare
Injection channels
for switching type
Auxiliary Outputs
Injection 2
Injection 3
Injection 4
Injection 5
Injection 6
Injection 7
Injection 8
Auxiliary Output 1
High Frequency
PWM or VVT
Control.
Three Wire ISC
Solenoid must be
wired to Aux1 and
Aux2.
Auxiliary Output 2
Auxiliary Output 3
Auxiliary Output 4
Auxiliary Output 5
PWM less than 300
Hz or general
switching
functions.
ISC Stepper
Auxiliary Output 6
Auxiliary Output 7
Auxiliary Output 8
Auxiliary Output 9
(E-throttle Motor +)
E Throttle Motor or
GP Output
Auxiliary Output 10
(E-throttle Motor -)
Knock 1
Knock Sensors
Only
Knock 2
Digital Input 1
Frequency Input,
Switch Input or
VVT Position
Digital Input 2
Digital Input 3
Digital Input 4
(Shared with An Volt 2 on Storm)
Digital Input 5
Frequency Input
or Switch Input
Digital Input 6
Digital Input 7
Switch Input Only
Digital Input 8
Digital Input 9
Digital Input 10
Installer IO Table